surface.
► Check heater before starting and regu-
larly during operation.
► Keep children and animal away from
heater.
► Always separate heater from mains
when not in use.
► Never fi t heater with a different bur-
ner or increase burner output over nomi-
nal power of heater as indicated on specifi
cation adhesive.
► Never block air inlet or outlet since this
could lead to ventilation motor overload
and consequently to overheating of unit.
WARNING! Only the burners
which are chosen and supplied
by the manufacturer can be used.
If another type of burner is used
the heater no longer complies
with CE regulations.
There are three safety devices which are
activated in case of serious malfunction.
The Burner Control Device, which is moun-
ted on the burner and has a restart but-
ton, automatically stops the burner if the fl
ame goes out. The Overheat Thermostat,
TS, of the manuel restart type, is activa-
ted if the temperature of the combustion
chamber rises above the set maximum li-
mit; the warning light (8) lights up and the
heater stops working. The Thermal Relay,
RT, is activated if the fan motor starts to
use more electrical current than the maxi-
mum permitted limit; the warning light (9)
lights up and the heater stops working. If
any of these safety devices are activa-
ted you should check carefully what the
problem actually is before pressing the
restart button and starting the heater off
again (cfr. OBSERVED FAULTS, CAU-
SES AND REMEDIES). Overheat safety
thermostat, TSS, shuts down the heater if
air fl ow is not suffi cient to cool off com-
bustion chamber: the heater will restart
automatically as soon as the heater has
cooled down enough.
►►3. INSTALLATION
WARNING !!!: The following
operations must be carried out by
qualified personnel only.
ELECTRICAL
CONNECTIONS
SETTINGS.
WARNING !!!: The mains supply
to the heater must be earthed and
have a magneto-thermal switch
with differential. The power cord
must be connected to a switch
board which has a disconnecting
switch.
The following operations must now be
carried out:
► Plug in the power cord having read the
adhesive label which
supply characteristics.
► Connect accessories such as the room
thermostat or clock to the unit's electric
switchboard: electric wire must be con-
nected by means of the cable fastener
(7) to the terminals. Having completed all
these operations check carefully that all
electrical connections correspond to the
wiring diagram and check the setting of
thermostat TV (cf. Technical Specifi ca-
tions). When the heater is fi rst turned on
you must check that the fan does not use
more current than the maximum permitted
limit. Finally, to regulate the burner follow
the instructions in the Burner Instruction
Manual.
CONNECTION TO HOT AIR DUCTS
(fig. 2)
The heaters can be delivered with follo-
wing accessories: 4-way air outlet cones.
The new head with the exception of the
"plenum", may be connected to new air
ducts if the user wishes to satisfy specifi
AL
BG
CN
CZ
DE
DK
AND
EE
ES
FI
FR
GB
GR
HR
HU
IT
details electricity
LT
LV
NL
NO
PL
PT
RO
RU
SE
SI
SK
TR
UA
YU