English
The following instructions contain important safety
information.
• Prior to installation please read carefully these instructions
(especially the "Safety Notices").
• Keep these instructions to consult them after installation if
necessary.
• Unsuitable application or wrong installation may result in a loss of
system operating functions and consequently in damages or/and
injuries.
•
The actuator is designed for applications on top hinged windows,
rooflights (or top hinged windows with windowsill) and bottom hinged
windows.
• The actuator is for internal use only.
• Only original parts and fittings shall be used to install the actuator.
•
The working temperature of actuators are: -10° C +60 ° C with
maximum relative humidity 60%.
N O T ES O N T H E A C T U A T O R
• Possibility
of
connection
synchronization of the speed of the chains.
• Possibility of parallel connection to operate more windows
simultaneously.
• Electronic stop in end-stroke positions. Check if the frame is
strong enough and if the bracket is firmly fastened (PVC
frames).
•
Protection in case of overload.
W A R N IN G : SA F ET Y N O T IC ES
• The actuator is to be mounted only on windows such that the
window moving parts and the operator be located more than 8
feet (2.44 m) above the floor or any other access level.
• Bottom hinged windows must be provided with side checks.
• The actuator shall be installed by skilled engineers.
• Prior to installation make sure that:
- the actuator performances comply with the estimated application
- window profiles and fittings are suitable to the stresses caused by
the actuator
- window fittings (hinges) and absence of obstacles allow complete
opening
- the existing electric systems comply with the regulations in force
- power supply features are those indicated in the actuator
specifications
Doc. 84074M - Rev. 30/07/09
of
two
or
more
actuators
• Interconnection wiring between the parts of the operator shall be in
compliance with National Electric Code and relevant local codes,
suitably routed and protected as per the National Electric Code and
relevant local codes.
• Before connecting the actuator to power supply make sure it has
been turned off to avoid electrocution.
• It's very important to verify that the grounding connection works
propely.
• An omnipolar switch shall be provided in the supply mains
(according to CEI EN 60335-1).
• Protect the field wiring by routing it in cable ducts.
• In case the actuator is installed on a mobile wing, make sure the
supply cable is not subject to stress when operating.
• When assembling and disassembling the actuator, take proper
precautions to avoid accidental closing of the window which might
cause injuries to people (impact-squashing-cutting-shearing).
• Minimum window height: on windows less then 1500 mm high
use the pivoting brackets.
• By feeding the actuator make sure that operation is regular and that
opening and closing limit switches operate correctly.
• When operating the actuator follow the following instructions:
- prevent liquids from entering the actuator
with
- do not approach moving parts until they have come to a complete
stop
- at least once a year check at sight for damages or wear in the
supply cable
- to open the window in case of power failure, remove the "split pin"
(D).
-
do not carry out any intervention on the actuator, do not
remove or disassemble parts of the actuator:
in case of malfunction or damaged cable contact "UCS
Ultraflex Control Systems srl".
ASSEMBLING INSTRUCTIONS
Installation on top hinged windows with windowsill or
• Mark the centre-line of the wing and drill the holes.
• Fasten the connector "A" with the supplied screws. The actuator has
to be fastened directly on the window sill by the screws "B" (not
supplied). In case of windows less than 1500 mm high the pivoting
brackets "C" has to be used.The pivoting brackets are right and left
hand.
• Warning: the chain push rod and the slit of connector "A" shall be
aligned.
•
Fasten the chain to connector "A" with screw+washer "D".
5 - 7
rooflights (picture 1)
Dis. 26643