INSTALLATION
CAUTION!
Risk of stumbling! Do not lay the cables in the running area.
Alarm 3 and Alarm 10
Fix the cable of the ball contact switch after approx. 35cm to
the wall, to relief any strain, with the cable holder and hose
clip, install the submersible ball contact switch at the desired
height, by fixing it to the pressure pipe of the pump, for examp-
le. Keep the connection length as short as possible (50 to 100
mm).
Alarm and Alarm&Stop
Place the electrode on the floor, as close as possible to the
appliances that are to be monitored. If, for example, the elec-
trode comes into contact with water as a result of a washing
machine leak, the alarm will sound. After the alarm has been
triggered, dry the electrode with a cloth.