Dip-Switch Functions - Beninca CP.K3-RE Manual De Instrucciones

Central de mando
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
TCA
Adjustment of the automatic close time if enabled by Dip-Switch 1.
Adjustment ranges from 1 sec to max 90 sec
AMP-O
Adjustment of the amperometric sensor obstacle detection sensitivity during the open
cycle.
AMP-C
Adjustment of the amperometric sensor obstacle detection sensitivity during the close
cycle.
Adjustment of trimmers AMP-O and AMP-C must comply with statutory
regulations.
If an obstacle is detected:
When opening, the gate is stopped.
When closing, the gate stops and opens for about 3 sec.
DIP 1 "TCA"
DIP 2 "PRELAM."
DIP 3 "UP"
DIP 4 "P.P. Mod"
DIP 5 "Fast AMP "
DIP 6 "COND."
DIP 7 "SoftSTART"
DIP 8 "Radio"
8
Trimmer functions

Dip-Switch functions

Enables or disables automatic closing.
Off: automatic closing disabled
On: automatic closing enabled
Enables or disables pre-flashing
Off: Pre-flash disabled
On: Pre-flash enabled. The beacon flashes for 3 sec before the motor starts.
Enables or disables the "Manned" function
Off: Manned function disabled.
On: Manned function enabled.
Only the OPEN/CLOSE controls are enabled: these buttons must be kept
pressed throughout the whole cycle (i.e. direct control of gate actions).
PHOT and P.P. inputs and PROXIMITY disabled.
Amperometric sensor and STOP enabled.
Selects the operating mode for the " P.P. button" and the transmitter.
Off: operating sequence: OPEN > STOP > CLOSE > STOP >
On: operating sequence: OPEN > CLOSE > OPEN >
Enables or disables the rapid amperometric function.
Off: in the close cycle the amperometric sensor detects the speed of variation
in current, regardless of the threshold adjustment by the trimmer, and reacts
rapidly to an obstacle.
This function raises the sensitivity of the amperometric sensor, increasing the
safety of the gate automation.
To use this function the gate has to be perfectly balanced and routinely checked
to avoid false sensor trips.
On: Function disabled. The reaction time of the amperometric sensor when an
obstacle is detected is normal.
Enables or disables the high traffic function.
Off: High traffic function disabled.
On: High traffic function enabled. The P.P. (Step-by-step) or transmitter signal is
ignored during the open cycle and the TCA cycle (if enabled).
Enables or disables soft start function.
Off: Function disabled.
On: Function enabled. The first 3 sec of the stroke are at a slower speed. This
avoids unduly stressing the mechanics.
Only for "RI" versions. Enables or disables transmitters with programmable
codes
On: Radio receiver enabled exclusively for rolling-code transmitters.
Off: Receiver enabled for both rolling-code and programmable transmitters
(self-learn and dip-switch) .
Tabla de contenido
loading

Este manual también es adecuado para:

Cp.k3-riCp.k4-reCp.k4-ri

Tabla de contenido