Fig.6 shows how to connect the fan with
timer utilising the same switch as for
the lighting.
To set the timer, turn the potentiometer
on the printed circuit board (fig. 7):
- To reduce the «run on» time, turn
anticlockwise (min. 1 minutes)
- To increase the «run on» time , turn
clockwise (max: 30 minutes).
DECOR-100 CH and CHZ
Models provided with an electronic
humidistat which can be adjusted from
60% to 90 % RH (relative humidity) and
with a timer, adjustable between 2 and
20 minutes.
Operation
Case 1: Automatic operation (fig.8)
In automatic operation, the humidistat
causes the extractor to operate
automatically when the humidity level in
the room is higher than the set level. The
extractor will stop automatically when
the humidity drops below the selected
level and after the selected period set
on the timer.
Case 2: Automatic operation as in case 1
with the facility to override the hygrostat
by means of the light switch (fig.6), when
the humidity level in the room is lower
than the selected level. In this case, the
extractor continues to operate for the
selected period set on the timer after the
switch light has been switched off.
ATENTION: When the himidity rate
is above the selected value, the
automatic option takes precedence
over the manual and the unit cannot
then be switched off using a switch.
The desired humidity level is selected
by means of a potentiometer "% Hr"
positioned on the printed circuit board
(fig. 9) and accessible once the grille (1)
has been removed.
- To increase the humidity setting turn
anticlockwise (min.60 %)
- To reduce the humidity setting turn
clockwise (max. 90 %)
To set the timer, turn the potentiometer
"t min." on the printed circuit board
(fig. 9):
- To reduce the «run on» time, turn
anticlockwise (min. 2 minutes)
- To increase the «run on» time , turn
clockwise (max: 20 minutes).
DECOR-100 CD and CDZ
Models provided with a PIR (passive
infra-red) detector. The unit starts
automatically when a movement is
detected with a maximum distance of
4 metres (fig.8).
They are also fitted with an adjustable
"run on" timer (1 to 30 minutes), and the
unit will continue to operate for the set
period after initiation by the movement
detector.
To set the temporisation, turn the
potentiometer on the printed board
(fig.7):
- To reduce the "run on" time, turn
anticlockwise (min. 1 minute)
- To increase the "run on" time, turn
clockwise (max: 30 minutes).
Maintenance
The extractor fan only requires periodical
cleaning using a cloth lightly impregnated
with a soft detergent.
After Sales Service
We recommend you not to try to
dismantle or remove any other parts
than those mentioned as any tampering
would automatically cancel the S&P
guarantee. If you detect any fault,
contact your S&P dealer.