Oase DC/DMX/02 Instrucciones De Uso página 15

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Start-up
This unit supports the DMX protocol extension RDM.
• Start-up and operation are only possible with a DMX-RDM controller.
• The DMX / RDM protocol is used for signal transmission and control.
Addressing via DMX
DMX (Digital Multiplex) is a standardised digital transmission protocol used in stage and event equipment as well as in
many Oase components.
The DMX channel and the mode can be changed by means of a DMX controller (WECS made by OASE). Read the
corresponding operating instructions
Description
Value
Serial No. (SN)
Enter the unit serial number. The serial number is indicated on
the type plate .
Product ID
50
Version No.
1
DMX Channel
Define the DMX channel. The factory-set channel is indicated on
the type plate
Configuration mode
1 = Define the first DMX channel (starting address)
− In the standard setting with four DMX channels, the three
following DMX channels are automatically allocated once the
starting address has been defined.
Addressing via DMX-RDM
RDM (Remote Device Management) is a new, open and bi-directional protocol standard for DMX-controlled devices.
The permanently transmitted DMX data flow briefly pauses (several milliseconds), and an RDM data package (messa-
ge) is sent directly to a subscriber. The subscriber evaluates the information in the data package and sends an answer
(semi-duplex) on the same line. Targeted polling to a subscriber via its UID (Unique ID) prevents several subscribers
from answering simultaneously.
The protocol makes it possible to receive status information about a unit or to change configurations on a unit. Chan-
ging the configuration means, e.g. changing the DMX address. The prerequisite for this function is a RDM-compatible
controller. Read the corresponding operating instructions
All unit outputs can be accessed individually and simultaneously. Two different operating modes can be selected. The
operating mode can only be configured by means of the Personality ID via RDM.
Personality ID
Description of operating mode
(Operating mode)
1
A DMX address controls a switch
(Standard)
subject to the DMX value range
A DMX address controls all switches
2
subject to the DMX value range
30539-10-13_GA_Underwater Switch15 15
.
RDM display text
Multi Channel Mode
Single Channel Mode
Underwater Switch
24 V DC/DMX/02
SN:
PRI
: 24VDC
10,5A max.
SEC
: 24VDC
4x2,5A max.
SN: 123456789
P
: 4x60W
max
max. 35°C
4 m
IP68
GmbH
OASE
Tecklenburger Str. 161, 48477 Hörstel, Germany
Number of DMX chan-
nels
starting address
4
1
29.10.2013 10:16:30
- GB -
56411

01234
12
123456789
DMX range
1 ... 509
1 ... 512
15
Tabla de contenido
loading

Este manual también es adecuado para:

56411

Tabla de contenido