AF9800
F - CROUZET – XD-10 Controller
The first LCD display to appear is the Input/Output image table and the Real Time clock.
An i/o no. indicates inactive i/o while a darkened i/o no. indicates an active i/o.
Updating time & date.
1. press OK key.
2. Move to MISCELLANEOUS line by pressing [ - ] key twice and press [ OK ] key.
3. Move to CLOCK line by pressing [ - ] key and press the [ OK ] key.
4. On DATE/HOUR SETUP press the [ OK ] key and move to the required field using
[ - ]/ [ + ] keys.
When the required field blinking and darkened , Press the [ OK ] key - the field is
blinking but not darkened, in this state use the [ - ]/ [ + ] keys to change the field
value.
When done, press the [ OK ] key to enter the new value - the field is blinking and
darkened again.
5. Move to other fields or exit to the main screen by pressing the [ ESC] key until the
main Screen appears.
PARAMETERS CHANGE/UPDATE PROCEDURE.
When a desire parameter screen displayed , it's value is darkened with black dotes.
(In case of parameter with two fields like DP ON/OFF TM use the [ - ]/ [ + ] keys to
move between them.)
To change a value –
A. Press the [ OK ] key > the value is blinking without the darkened dots.
B. Change the value by pressing the [ - ]/ [ + ] keys.
(Note that you can hold the [ - ]/ [ + ] keys for fast change or to click them for
slow change.)
C. When done press the [ OK ] key to enter the new value > the new value is
darkened with black dotes again.
D. Move to the next parameter by pressing the [ A ] key again or exit by pressing
the [ESC] Key.
- PLC inputs display.
- PLC outputs display.
- Time display.
- PLC run indication.(rotating)
- PLC operation keys
28