Sears Kenmore Pro 79079523605 Instrucciones De Instalación página 4

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

30" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
Three Conductor Wire Connection to Range
(The 3-conductor cord or cable must be replaced with
a 4-conductor cord or cable where grounding through
the neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas
where local codes do not permit neutral grounding)
If local codes permit connection of the frame grounding
conductor to the neutral wire of the power supply cord
(see Figure 3):
1. Remove the 2
screws at the
lower end of
the rear wire
access cover, then
remove the access
cover to expose
range terminal
connection block
(see Figure 2).
Pressure regulator
Risk of fire or electrical shock exists
if an incorrect size range cord kit is used, if the
Installation Instructions are not followed, or if the
strain relief bracket is discarded.
2. Remove the 3 loose nuts on the terminal block using
3/8" nut driver or socket.
3. Connect the neutral white wire of the power supply
cord to the center silver-colored terminal of the
terminal block, and connect the other wires to the
outer terminals. Match terminal and power supply
wires by color.
4. Replace the 3 nuts on the terminal block (see figure
3).
5. Replace the rear wire access cover using the 2 screws
removed on step 1.
Terminal
Block
Black
wire
A strainrelief
supplied by the
To 240V
user must be
receptacle
installed at this location
Figure 3
(Model with Electric Oven and Gas Cooktop)
Rear wire
access cover
location
Figure 2
Silver Colored
Terminal
Red
wire
White wire
(neutral)
Grounding
Strap
1-1/8" Dia. Direct
Connection Hole.
Punch out knockout
for 1-3/8" Dia.
Cord Kit Hole
Four Conductor Wire Connection to Range
(mobile homes)
1. Remove the 2 screws at the lower end of the rear wire
access cover, then remove the access cover to expose
range terminal connection block (see Figure 2).
2. Remove the three loose nuts (after you removed the
rubber band) on the terminal block using a 3/8" nut
driver or socket.
3. Remove the grounding strap from the terminal block
and from the appliance frame.
4. Connect the ground wire (green) of the power supply
cord to the frame of the appliance with the ground
screw, using the hole in the frame where the ground
strap was removed (see Figure 4).
5. Connect the neutral wire of the power supply cord
to the center silver-colored terminal of the terminal
block, and connect the other wires to the outer
terminals. Match terminal and power supply wires by
color.
6. Replace the 3 nuts on the terminal block (see figure
4).
7. Replace the terminal cover using the 2 screws
removed on step 1.
Terminal
Block
1-1/8" Dia.
Black
Direct
wire
Connection
Hole. Punch
out knockout
for 1-3/8" Dia.
Cord Kit Hole
A user supplied
strain-relief must
be installed at this
location.
NOTE: Be sure to remove the
supplied grounding strap.
4
Silver Colored
Terminal
Red
wire
White
wire (neutral)
Ground (Bare
Copper Wire)
To 240 V receptacle
Figure 4
Tabla de contenido
loading

Tabla de contenido