REAR PANEL

8. Ethernet Connection
This connection is for standard RJ-45 cables, used
for 10/100 Ethernet control� Using a CAT5 twisted pair
copper cable, Asystems doesn't recommend a distance
of more than 100 meters to the nearest computer or
hub� The Ethernet connection is used to control the
software via the PC control software and the RM-6E
programmable remote controls�
9. Euroblock Line Inputs
The DMP801 offers a total of eight line input channels�
These inputs are active balanced with euroblock
connectors� If an unbalanced signal is used, Asystems
advises that customers ground the unused conductor�
10. Mix Output
The DMP801 offers a single 3-pin Euroblock output�
These are servo-balanced euroblock connectors and can
be wired to either balanced or unbalanced connections�
11. Channel Inserts
Each of the 8 line input channels has its own insert point
through ¼" TRS phone jack� These accept standard
phone jack y-cables where the tip is used to send signals
from the DMP801 and the ring is used to return signals
back to the device�
15
English
13
14
8
12
12. Unit ID Controls
The Unit ID controls consist of a single rotary switch as
well as 8-pin DIP switch� These essentially adjust various
controls and settings as well as things like firmware
updates� More information on Unit ID settings can be
found in the relevant area of this manual� These controls
extend to IP address settings and initialization�
13. RS232 Connector
This standard RS232 connector is for third party control
systems� The Asystems control software does not work
through RS232, rather the RS232 port provides a simple
means for external control systems to be applied to the
DMP801�
14. 24VDC Input
This connector is used for emergency power to the
DMP801� This input connector can be used with a 24VDC
battery or power supply to ensure operation continues in
the event of power outage�
15. AC Power Connector
This is for a standard IEC power cable�