Controller operation
See hydronic module documentation.
Heating / cooling mode
See hydronic module documentation.
Zone 2 has independent climatic curve settings.
If room temperature is measured by the system (code 105.0=1
or 2 or 4 for zone 1; code 105.1=1 or 2 or 4 for zone 2), water
Domestic hot water function
See hydronic module documentation.
Room priority is calculated for both zones.
Frost protection
See hydronic module documentation.
It is active for both zones
Home antifreeze protection
See hydronic module documentation.
If enabled, it works only if room temperature is measured by
Water pump management
See hydronic module documentation.
To enable this function in zone 1, set code 1.6=1; to enable it
in zone 2, set code 1.7=1.
Pump unblocking procedure
See hydronic module documentation.
It is active for both zones
Valve operation
3 way valve is controlled to make sure TW1 temperature
is corresponding to zone 1 water setpoint, determined as
described in paragraph Heating/cooling mode.
setpoint calculated through climatic curves
is adjusted so that the room temperature matches the room
setpoint.
the system (code 105.0=1 or 2 or 4 for zone 1; code 105.1=1
or 2 or 4 for zone 2).
If enabled, it works only if room temperature is measured by
the system (code 105.0=1 or 2 or 4 for zone 1; code 105.1=1
or 2 or 4 for zone 2).
80AW9025
9