Briteq Club Laser 7 Manual De Instrucciones página 4

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
ENGLISH
LASER SAFETY INSTRUCTIONS:
 According to the EN 60825-1:1994 + A1:2002 + A2:2002 regulations, this laser falls under the
classification 3B. Direct eye exposure can be dangerous.
DANGER: LASER RADIATION !
Avoid direct eye exposure! Laser radiation can cause eye damage
and/or skin damage. All protective measures for a safe operation of
this laser must be applied.
 This product is a so-called show laser, emitting radiation with a wavelength spectrum between 400 and
700 nm and producing lighting effects for shows.
 Due to the construction of this laser, the beam is moved so fast, that it can only hit the eye very short. This
is why the use of this laser for a Laser-Light-Show can be regarded as save.
 Never direct the laser beam to people or animals and never leave this device running unattended.
 This laser may only be used for shows. The operation of a class 3B show laser is only allowed if the
operation is controlled by a skilled and well-trained operator.
 Depending on the classification, operating a laser product can produce laser radiation that may cause
permanent eye damage and/or skin damage. The legal instructions for using a laser product vary from
country to country. The user must always inform himself on the legal instructions valid in his country and
apply them to his situation.
Please note that BRITEQ cannot be made liable for damages caused by incorrect installations and unskilled
operation!
DESCRIPTION:
1. MAIN ON/OFF SWITCH: used to switch the unit on/off.
2. MAINS INPUT: with IEC socket and integrated fuse holder, connect the supplied mains cable here.
3. COOLING FAN (input): used to cool the components inside the enclosure. Make sure that the filter
inside the fan is always in place before you turn the laser on! The filter should be cleaned on a regular
base! Just tear off the plastic cover and clean the filter with a vacuum cleaner.
4. COOLING FAN (output): used to cool the components inside the enclosure. Make sure to never cover
this fan outlet!
5. HANGING BRACKET: with 2 knobs on both sides to fasten the unit and a mounting hole to fix a
mounting hook.
BRITEQ
®
USER MANUAL
3/51
CLUB LASER 7
ENGLISH
6. SAFETY EYE: used to attach a safety cable when the unit is rigged (see paragraph "overhead rigging")
7. ON/OFF KEY ACTIVATED SWITCH: used to switch the laser beam on/off. Use the keys to make sure
only a skilled operator is able to switch the laser on.
8. INTERLOCK input: used to connect the optional emergency stop switch (see picture). When you push
this switch the laser beam will disappear immediately.
IMPORTANT! For your own safety we strongly recommend
to connect this optional switch!
9. DISPLAY: shows the selected DMX address when the unit is in
DMX-mode. Apart from DMX-mode you can also select 4 other
working modes, see further to learn more about these modes.
10. DIP-SWITCHES: switches 1~8 are used to set the DMX address
between 000 and 255. Switches 9 and 10 are used to select the
desired user mode.
11. DMX OUTPUT: 3pin female XLR-connector used to connect the
laser with the next unit in the DMX chain.
12. DMX INPUT: 3pin male XLR-connector used to connect universal DMX-cables. This input receives
instructions from a DMX-controller.
13. INTERNAL MICROPHONE: The built-in microphone is used to synchronize the laser show to the beat of
the music.
14. MUSIC INPUT SENSITIVITY: This potentiometer is used to adjust the music input sensitivity. Turn the
potentiometer until the laser works in sync with the music.
15. X/Y SIZE CONTROL: use these controls to adapt the size of the projected graphics to the dimensions of
the venue. You can change the vertical and horizontal size independently.
16. X/Y MIRROR CONTROL: use these controls to mirror (reverse) the projections. This is for example
useful when you project graphics from behind a transparent screen.
17. ILDA INPUT: used to connect the laser to an ILDA certified interface of a computer, see further for more
information.
18. ILDA THROUGH: to link the ILDA signal to the next "Club laser 7" unit.
19. LASER OUTPUT: Here the laser beam leaves the enclosure, make sure to NEVER look inside the unit
through this opening while the laser effect is switched on!
20. POWER LED: indicates that the unit is switched on.
21. DMX LED: indicator is lit when the laser detects a DMX-signal.
22. WARNING LABEL: "Caution – Class 3B laser. Laser Radiation when open. Avoid exposure to beam."
23. WARNING LABEL: "Laser Radiation. Avoid exposure to beam. Class 3B laser product"
24. LASER WARNING SIGN: warns against a potentially dangerous laser when not used by skilled
operators.
25. WARNING LABEL: "Laser Aperture"
BRITEQ
®
USER MANUAL
4/51
CLUB LASER 7
Tabla de contenido
loading

Tabla de contenido