Pontec PonDuett 3000 Instrucciones De Uso página 10

Ocultar thumbs Ver también para PonDuett 3000:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
- EN -
Cleaning the device
Unscrew the nozzle tube or stepped hose adapter with O ring 12x4 from the connection thread (A), open the engage-
ment hooks on both sides of the filter housing and remove the top strainer casing (B). Take the pump out of the top
foam filter, remove the foam filters, the gravel bags and the biosurface elements from the bottom strainer casing (C).
Unscrew the pump lid or the pump housing (D) and remove the impeller. Clean the impeller (E) and strainer casings
using clear water and a brush, rinse the foam filters, gravel bags and biosurface elements under running water. After
cleaning, fit the unit in the reverse order.
Storage/overwintering
The unit is not frost-proof and has to be removed and put into storage if minus temperatures are expected.
How to correctly store the unit:
· Thoroughly clean the unit, check it for damage and replace any damaged parts.
· Store the pump submerged and in a frost-free environment.
· Protect open plug connections from moisture and dirt.
Wear parts
· Foam filters
· Impeller
Disposal
N O T E
Do not dispose of this unit with domestic waste.
· Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
Malfunctions
Malfunction
The unit is not operating
Insufficient delivery rate
Unit switches off after a short running period
Guarantee conditions
PfG grants a 2 year guarantee from the date of sale on proven material and manufacturing faults. Wear parts such as
bulbs etc. are exempted from the guarantee. Prerequisite for our guarantee is the presentation of the purchase receipt.
Our guarantee will become null and void if the unit is misused, electrically or mechanically damaged by inappropriate
use and improper repair by non-authorised workshops. Repairs are reserved for workshops authorised by PfG or by
PfG itself. In the case of warranty claims, please return the defective unit or part freight paid to PfG together with a de-
scription of the fault and the purchase receipt. PfG reserves the right to invoice repair costs. PfG is not liable for
transport damage. Any damage must be claimed against the carrier. Further claims of whatever type, especially conse-
quential damage, are excluded. This guarantee does not affect the final customer's claims against the dealer.
10
Cause
No mains voltage
Impeller blocked
Strainer casing clogged
Foam filter clogged
Water temperature too high
Remedy
Check mains voltage
Clean impeller
Clean strainer casing
Clean foam filter
Note maximum water temperature of +35°C
Tabla de contenido
loading

Este manual también es adecuado para:

Ponduett 5000

Tabla de contenido