FAQ. Question
Answer
Can I use the ONE
YES. To manage the double barrier
system to manage a
LIMIT-ONE, you have to use two ONE
synchronised double
control units, one for each barrier, setting
barrier?
one as MASTER and the other as SLAVE
(using the dip switch #10 of the control
unit). In this way, the MASTER control
unit communicates with the SLAVE,
synchronising their movements.
In the MASTER-SLAVE
In synchronised applications (MASTER-
applications, where do I
SLAVE), the accessories must be
connect the accessories
connected only on the MASTER BUS line.
to the BUS?
Which are the dip-switches possible settings?
1
2
3
4
5
6
7
8
9
O
N
DIP 1 OFF = End limit override disabled
DIP 1 ON = End limit override enabled (500ms)
O
1
2
3
4
5
6
7
8
9
N
DIP 2 ON = Setting for deceleration after 60% of stroke in closing
DIP 2 OFF = Setting for deceleration after 80% of stroke in closing
O
1
2
3
4
5
6
7
8
9
N
DIP 3 ON = Setting for deceleration after 60% of stroke in opening
DIP 3 OFF = Setting for deceleration after 80% of stroke in opening
1
2
3
4
5
6
7
8
9
O
N
DIP 4 ON = Automatic Closing enabled (pause time 30 sec)
O
1
2
3
4
5
6
7
8
9
N
DIP 5 ON = LED Strip always ON
DIP 5 OFF = LED Strip only ON when operator is operating
1
2
3
4
5
6
7
8
9
O
N
DIP 6 ON = Steady light
DIP 6 OFF = Flashing light
O
1
2
3
4
5
6
7
8
9
N
DIP 7 ON = Auxiliary Flashing Light
DIP 7 OFF = Electric Lock Command
1
2
3
4
5
6
7
8
9
O
N
DIP 9 ON = Slave control unit
DIP 9 OFF = Master control unit
1
2
3
4
5
6
7
8
9
O
N
DIP-SWITCH 10 ON = DS Disabled
DIP-SWITCH 10 OFF = DS Enabled
10
10
10
10
10
10
10
10
10