4. The lowest fitting is designated for the
suction line to the pump.
5. The middle fitting is designated for the
recirculation/bypass line returning from the
valve manifold.
6. The top fitting on the reservoir should be
connected as an overflow pipe or as an auto-fill.
If used as an overflow pipe, it should run to a
French drain or other overflow area.
7. The ¾ HP Pump (8) and 25sf Filter/Chlorinator
(9) should be setup as shown in FIGURE 3.
8. The ¾ HP Pump (8) and 25sf Filter/Chlorinator
(9) require 1 ½" PVC pipe for both inlet and
outlet.
9. The inlet of the pump should be connected to
the lowest 1 ½" fitting on the reservoir; the
maximum height for the self-priming pump
above the waterline in the reservoir is 7 ft.
10. The pump outlet should run directly to the
filter/chlorinator.
11. From the filter/chlorinator to the valve manifold
the pipe should stay at 1 ½" as long as possible
to reduce pressure loss in the pipe, but it needs
to be scaled down to 1" before the valve
manifold.
12. The pump for the stand alone version of the WetDek should be wired directly to the control box that
comes with the WetDek. THIS CONNECTION MUST BE DONE BY A LICENSED ELECTRICIAN.
This will regulate when the pump runs in unison with the valves. The pump and controller run off of a
115 Volt power source. The WetDek AquaDirector Controller (1) is rated as a NEMA 3R enclosure,
which allows it to be placed indoors or outdoors.
FIGURE 4
5
13. The valve manifold for the Stand Alone version
should be setup as shown in FIGURE 4.
14. Each of the 1" Manifold Tees (4) should be
attached to one of the 1" HPV Valves (3). This is
done by threading the male portion of the
manifold tee to the female inlet side of the valve.
It is important to insure that the valve is placed
in the correct direction for the system to work
properly.
15. It is also important to insure that the valves are
all in the same orientation before attaching the
Manifold Tees (4) as shown in FIGURE 4.
16. The Manifold Tees (4) should first be wiped with
a PVC Primer and then given a liberal amount of
PVC Glue on one of the surfaces before
connecting the male and female ends.
17. The first three valves will each connect to one of
the
zones
controlled
AquaDirector Controller. The order is not
important.
18. The
fourth
valve
recirculation function that is vital for the Stand
Alone version of the WetDek to insure that the
water remains clean.
19. The last portion of the valve manifold should
connect the 1" Globe Valve (5) from the end of
the valve manifold to the same line as the
recirculation line, as shown in FIGURE 4. This
will work as a bypass and will allow you to
manually adjust the heights of the water spray
for the whole system.
FIGURE 3
by
the
WetDek
will
control
the
daily