Cooper Lighting MS100PG Manual De Instrucciones página 5

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

activating the wall switch. The floodlight will turn on as it warms up for about 1
minute, then it will turn off.
3.
Aim sensor head toward desired detection area.
4.
Walk across the detection zone at the farthest distance you wish your detector
to detect motion.
5.
Position the motion sensor so that it senses motion in the area you want.
For a smaller coverage area, point the sensor down. For a larger coverage
area, point the sensor up.
Set the Time Adjustment Control
Rotating the time adjustment knob will control how
long the light stays on after motion is detected (from
5 seconds to about 12 minutes).
1.
Turn the knob clockwise to increase the amount
of time (Fig. 6).
Set the Light Adjustment Control
Rotating the light adjustment knob will control at what level of brightness the
motion sensor will turn the light on when it is in automatic mode (not test mode).
1.
Turn the light control knob all the way clockwise
to the moon symbol (dusk position) (Fig. 7).
2.
When it is dark enough that you want the light to switch on,
slowly turn the knob counter clockwise until the light becomes
active. This will set your flood light to activate when it is dark
and stay off during day light hours.
HOW TO SELECT YOUR DESIRED FEATURE
Mode of
Operation:
Auto setting
(motion activated)
Light should turn on with motion
only at night and should turn
off and on according to the light
level selected by the light
adjustment knob.
Standard Floodlight Setting
(Manual Override)
Light should stay on
continuously both day and
night (must be reset manually).
Test Setting
Light should turn on with
motion both day and night.
Light should turn off after
4 seconds, if time setting is in
"T" position.
Call for customer service and/or missing or damaged parts (800-334-6871)
Set Knob
on Sensor to:
5 SECONDS
TO
12 MIN
Any Setting
TEST
(Both Knobs)
5
About 5
About 12
T
T
seconds
minutes
How to Set
Power Switch:
Keep the power to
the fixture on.
Unplug and plug once within 2
seconds to set back to Manual
Override Mode. Unplug for
10 seconds to reset to
Auto Mode.
Keep the power to the
fixture on.
Fig. 6
Fig. 7
Tabla de contenido
loading

Este manual también es adecuado para:

Cms100pg

Tabla de contenido