3.6 Input price
Press<0~9> and < . > key, or press <c> key to modify it.
3.7 Store and recall price
Press<store>, after display shows "M", press <0~9> or < .> key to input the price, and then press<m1~m7> to
store; press <m1~m7> to recall the stored price.
3.8 Accumulation and clear
3.8.1 Accumulation:
----Press<M+> after put the first piece of load on the pan and enter the
"add" and the accumulate frequency. Remove the first piece of load
----Put the second piece of load on, then press<M+> to add the second second accumulation event into
memory.
3.8.2 Accumulation display and clear:
Press <M+> key to display the total accumulation data in the total price, then press <c> to clear it.
3.9 Save power function
Zero after 3 seconds, auto save power, shows " - ". put a weight start weighing.
3.10 Battery indicate and charge
-- Battery charging time: 24 hours
-- One segment corresponds to approx.25% capacity
-- If the symbol flashes,the storage battery has to be charged.
--During charging the segments are "runing" until the battery is fully charged and all segments light up continuously.
4 CALIBRATION
Calibration Code: 200.94(211.99)
Ste
Operation
ps
1
Open scale, input password to start
2
Set decimal point
3
Set full capacity
4
Unload
5
Load standard weight
6
Input value of standard weight
Description
"UNIT PRICE" window shows"dec",
"TOTAL PRICE" window shows
default division
"UNIT PRICE" window shows"dot",
"TOTAL PRICE" window shows
decimal point of "Weight" window
"UNIT PRICE" window shows "FS",
"TOTAL PRICE" window shows
default max capacity
"UNIT PRICE" window shows
"Unload","TOTAL PRICE" window
shows zero code
"UNIT PRICE" window shows "-0-"
then "load", "TOTAL PRICE" window
shows different value between
current code and zero code
"UNIT PRICE" window shows
"input", "TOTAL PRICE" window
shows default calibration value, input
actual value of standard weight
price, the price display shows
Set
Press [1] to choose division
(10, 5, 2, 1 for option), press
[Tare] to confirm
Press [1] to choose division
Press numbers keys to set
FS
Press [Tare] to confirm,
calibration is finished.
P-3