Eikon
Arké
Idea
20540
19540
16980
Three simple buttons, to be completed with 1 or 2-module
buttons - 3 modules.
Device to be used as three single buttons or one single and one double, depending
on the button; it can be pressed at the bottom only.
CHARACTERISTICS.
• Rated supply voltage: BUS 29 V
• Input: 16 mA
• Button: 1 double, 1 single or 3 single ones
• Terminals: TP BUS
• Possible functions:
- state reversal (step-by-step)
- push button
- ON only
- OFF only
- scenario activation.
• Consist with:
- By-me flush and surface mounting control units, rel.2.0 and next
- By-me 2-module control units, rel. 2.0 and next
CONFIGURATION.
FOR THE OPERATIONS OF INSTALLATION AND CONFIGURATION, SEE THE
By-me SYSTEM INSTRUCTIONS MANUAL ATTACHED TO THE CONTROL UNIT.
Configuration must be done with the device without the button to be able to press
the central configuration button.
The device can be used as three single buttons or one double push-button and
a single one.
• Functional blocks: 3, each functional block can belong to at most 4 groups.
• Selecting the functional block (configuration): during group creation, when the
control unit requires pressing the device button:
- press the configuration button;
- if the device must be configured as three single push-buttons, within 3 s, press
the right-hand button to select the right functional unit, the middle button to select
the middle functional unit or the left-hand button to select the left functional unit;
the red LED illuminates. If none of the three buttons is pressed within approxi-
mately 3 s the red LED will light up; in this case the selected functional unit is the
third one, the one related to the actuator.
- if the device must be configured used as a double and a single push-button,
proceed as follows:
• configure the left functional unit in the case in which you want a push-button
with two modules on the left of the device (left button + middle button) and then
configure the right functional unit (right button);
• configure the middle functional unit in the case in which you want a push-button
with two modules on the right of the device (middle button + right button) and
then configure the left functional unit (left button).
- the red LED will come on and the control unit will configure the functional block;
at the end of the operation the red LED will go out.
.
PARAMETERS
• For each functional block it is possible to set the operating mode:
- simple button (ON when pressed, OFF when released);
- ON/OFF button (step-by-step);
- button ON only;
- button OFF only;
- scenario control.
• LED parameters:
- LED off;
- LED with normal operation (on if the associated actuator is ON);
- LED with reverse operation;
- LED always on for location in the dark;
- central LED with normal operation (Double button);
- central LED with reverse operation (Double button);
- central LED always on for location in the dark (Double button).
If the functional block belongs to more than one group, the "LED with normal
operation" and "LED with reverse operation" parameters are not available. In
these cases the control is confirmed by a LED status change for 3 s.
If a double key is used, it is necessary to set the central LED behaviour to make
the status visible. In this case, configure the left button if the double button is on
the left of the device or the middle button if the double button is on the right.
Viale Vicenza, 14 - I 36063 Marostica VI
Tel. +39 0424 488 600 - Fax (Export) +39 0424 488 709
www.vimar.com
Plana
14540
FRONT VIEW
.
A
Eikon
B
A
Idea
B
Caption
:
A: Configuration button
B: LED
BACK VIEW
.
• Default parameters: the buttons are set as ON/OFF push-buttons (step step).
INSTALLATION RULES.
Installation should be carried out observing current installation regulations for electri-
cal systems in the country where the products are installed. For further instructions,
please see the manual attached to the panel control.
CONFORMITY.
EMC directive
Standard EN 50428.
ENGLISH
Instruction sheet
A
Arké
B
A
Plana
B
Terminals TP bus