Expansion Options - ABNOX AXKP 1 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 49
EN

Expansion options

Pressure reduction valves DR1–3 (Figure G-I)
DR1: Pressure reduction valve 0-10 bar
DR2: Pressure reduction valve 0-10 bar with water
separator (air service unit)
DR3: Pressure reduction valve with additional com-
pressed air connection for metering valves with
handle
Technical Data
Electrical data
Connection
RatedDC operating
voltage
Rated
operating current (le)
Max. ready delay (tv)
Electrical design
Utilisation category
Max. hysteresis (H)
Relay output
Switching function
Switching frequency (f)
Max. operating voltage
DC (UB)
Min. operating voltage
DC (UB)
Wiring diagram: Figure L/no. 21
26
Connectors
24 DC V
130 mA
10 ms
DC
DC 13
15 %
PNP
Normally open (NO)
600 Hz
30 V
10 V
Electrical empty notification E / Electrical
refill-empty notification N (Figure J/L)
Electrical empty notification E:
Sends an electrical signal to an external system when
the container or cartridge is empty.
Electric refill-empty notification N:
Sends an electrical signal to an external system when
the container or cartridge has reached a preset
position. This present position warns the operator of
a low fill level. The refill notification can only be instal-
led with the empty notification option.
Mechanical data
Number of conductors
Rated switching offset (sn)
Diameter
Safe switching offset (Sa)
Mechanical installation
requirements
Ambient
temperature max.
Ambient
temperature min.
Degree of fouling
Active surface material
Housing material
Repeat accuracy
3 wire
4 mm
M12x1 mm
0...3.2 mm
Flush installation possible
+ 70°C
- 25°C
3
PA 12
CuZn, nickel plated
= 5 %