Care And Maintenance; Inserting New Spirals; Troubleshooting; Accessories - Rothenberger RODRUM M Serie Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
7

Care and Maintenance

Pull out the mains power plug before performing any servicing and mainte-
nance!
The machine is maintenance-free except for the feed unit.
Clean and grease the feed unit regularly and check it for damage. The ball bearings can be re-
placed if necessary.
The device should be handled carefully and cleaned regularly.
The spirals and tools should be cleaned and preserved after every use. We recommend use of
our special care product "ROWONAL".
All servicing, maintenance and repair work may only be performed by in-
structed specialist personnel!
7.1

Inserting new spirals

 Move the spirals with the feed unit completely from the drum and unfasten the coupling.
 Connect new spirals with the connecting piece and push in the spirals up to about 30cm.
8

Troubleshooting

Symptom
The machine does not start
No feed
9

Accessories

Accessory Name
Welder's glove left, leather
Welder's glove right, leather
Welder's glove Pair, rubber
ROWONAL rust remover (5 l)
ROWONAL spiral combi-spray (0.2 l)
Guide tube
Segregation key
Spiral 13 mm x 15 m, with bores
Spiral 16 mm x 15 m, with bores
Spiral 20 mm x 15 m, with bores
Further accessory parts
20
Possible Reason
No power supply
Motor defective
Switch off the PRCD
The foot switch / com-
pressed air hose is defective
Ball bearing in the feed unit
is defective
Spiral defective
ROTHENBERGER Part Number
72120
72121
1500000439
72140
72142
1000001850
72100
1500002271
72918
1500002268
www.rothenberger.com
ENGLISH
Solution
Check the power supply
network
Contact our Customer Ser-
vice Department
Press the RESET button
(PRCD)
Contact our Customer Ser-
vice Department
Contact our Customer Ser-
vice Department
Replace the spiral
Tabla de contenido
loading

Tabla de contenido