Function of the Unit

6.1
Overview
Guide tube
1
Lever
2
Feed unit
3
Foot switch
4
Drum
5
6.2

Transfer

6.2.1
Height adjustment of the transport handle
 Open both locking bolts and lock this through turning through 90°.
During opening, hold the handle in position.
 Select the suitable handle height. According to the application there are four selectable han-
dle settings. The lowest handle position is the setting for transport in a vehicle.
 Turn both locking bolts back into the locking position.
Ensure that both locking bolts audibly engage; if necessary check through light
shifting.
6.2.2
Loading the pipe cleaning machine
 Place the pipe cleaning machine backwards into the loading area of the vehicle.
 Select the suitable handle height according to 6.2.1.
 Tip the pipe cleaning machine with the transport wheel on the loading area of the vehicle.
 Raise the pipe cleaning machine with both hands and push this completely onto the loading
area.
When raising the pipe cleaning. select a back-
friendly operating method, crouch down first before
lifting with both hands or two people lift the pipe
cleaning machine as a pair.
 Place the pipe cleaning machine in the vehicle so that this does not slip during the drive.
Never transport the pipe cleaning machine lying down!
 Stow away the cable in a manner suitable for transport.
6.3

Commissioning

The pipe cleaning machine should exclusively be operated by instructed and
authorised personnel!
 Check the electrical installation at the work place.
 Place the foot switch in such a way that it can be easily reached and that all control ele-
ments are easy to operate.
 Push the guide tube over the spiral up to the dead stop on the feed unit housing and fix in
place with the catch.
 Connect the mains power plug to the appropriate power supply network.
Ensure that the motor switch is set to "OFF"!
Never use the cleaning device without a footswitch and guide hose!
Tool box
6
Locking bolt
7
Network cable with PRCD
8
Couplings (on the left: 20 mm square;
9
on the right: 16 mm T-groove)