i
technical Data
Motor series:
type:
i
Setting parameters on EIB/KNX shutter actuators for RADEMACHER tubular motors
The following parameters must be adjusted before commissioning to ensure the smooth
operation of RADEMACHER tubular motors with EIB/KNX shutter actuators:
Short-term operation
Where possible, short-term (slat adjustment) operation must be turned off.
E.g. short-term operating mode
time: = 0 ms
i
CE Mark and EC Conformity
Tubular motors of series RolloTube Comfort Small and Medium (item numbers.:
2540 06 36 / 2540 10 36 / 2560 10 96 / 2560 20 96 / 2560 30 96 / 2560 40 96) complies
with the requirements of the current European and national directives:
2006/42/EC Machinery directive
2006/95/EC Low voltage directive
2004/108/EC EMC directive
Conformity has been verified. The corresponding declarations and documentation are
available on file at the manufacturer's premises.
RADEMACHER Geräte-Elektronik GmbH & Co. KG
Buschkamp 7
46414 Rhede (Germany)
Small
6/28
10/16
10/16
20/16
6
10
10
20
28
16
16
16
230
230
230
230
50
50
50
50
121
121
112
145
0.53
0.53
0.49
0.64
4
4
4
4
5
5
5
5
0.75
0.75
0.75
0.75
3
3
3
3
32
32
32
32
H
H
H
H
I
I
I
IP 44
IP 44
IP 44
IP 44
*
*
*
*
462
462
465
465
35
35
45
45
3
3
2
2
Medium
30/16
40/16
30
40
[Nm]
[rpm]
16
16
230
230
[V]
50
50
[Hz]
191
198
[W]
0.83
0.86
[A]
[Min.]
4
4
5
5
0.75
0.75
[mm
]
2
[m]
3
3
32
32
[R]
H
H
I
I
I
IP 44
IP 44
*
*
524
524
[mm]
45
45
[mm]
2
2
If your software application does not support turning off short-term
operation...
...you must ensure that the time between short-term and long-term operation specified
for the touch sensor is shorter than the time between short-term and long-term operation
specified for the actuator.
This prevents the actuator from suddenly switching off when the sensor button is pressed.
Long-term operation
The motor must be de-energized at the latest after 180 seconds.
E.g. Basis for long-term operation
Basis:
Factor: = 86
Nominal torque:
Idle speed:
Rated voltage:
Frequency:
Nominal output:
Current consumption:
Operating time:
Number of cable cores:
Wire cross-section:
Cable length (standard):
Limit switch range (number of revolutions):
Insulation class:
Protection class:
Protection type in accordance with VDE 700:
Type of cable: (* =rubber)
Length of motor witout bearing:
Pipe diameter:
Number of parallel switchable tubular motors
(in case of using a RADEMACHER control, e.g. Troll Comfort)
= 2.1 s
= (2.1 s x 86 = 180.6 s)
EN