Technical Data
Model
Configuration
Medium intake
Compressed air connection
Max. working pressure
Ideal working pressure
Medium spec.
Pressure output A
Pneum. control air pressure
Voltage
Power consumption
Protection class
Plug
Switching frequency
Continuous sound pressure level
Dimensions
Assembly / Installation
The product is to be set up or installed at the inten-
ded use site under due consideration of the following
conditions:
• At the location and site all applicable provisions of
law must be clarified and compliance with them
assured.
• The ground and space relations are to be clarified
prior to set-up/installation of the product in order
to assure safe operation for the personnel and the
product long-term. The product must be set-up/
installed so that safe, permanent operation is
assured.
• The product may only be set up and commissioned
by specially trained technicians.
• The product is constructed for rooms that are pro-
tected from the influence of the weather (industry
standard).
• The operation and storage in aggressive or humid
environments or outdoors can lead to corrosion
damages.
• The valves can be installed in any position.
• The distance to the application surface depends on
the desired application pattern.
AXDV-P1
Nozzle Ø 0.2 - 1.5 mm
G1/8"
M3 for hose Ø 4 mm
100 bar, depending on control air/counter pressure
Approx. 40 bar, depending on lubricant viscosity
Lubricants up to NLGI 3 / max. 1,000,000 m Pas
With integrated nozzle, diameter according to
configuration
Max. 7 bar
24 VDC (+/- 10%)
2 W
IP40
M-plug with 0.3m connection cable
Up to 100 HZ
76 dB
See measurement sheet
• Intermittent valve operation results in natural reso-
nance. Therefore, it is necessary to ensure that the
valve is firmly mounted using the three mounting
bores provided (Figure D/No. 10). Excessive natural
resonance (transferred from the machine to the
valve) must be prevented.
EN
21