TANK AND VACUUM GRID WITH FLOAT CLEANING, AND COVER GASKET CHECK
1.
Drive the machine on a level floor.
2.
Ensure that the machine is off and the ignition key (40)
has been removed.
3.
Turn the recovery tank lid (A, Figure 23) 90 degree
position where it can be took off from the tank, and then
take down the float ball filter (P) from the tank.
4.
Clean the recovery tank lid (A), recovery tank (B), clean
water tank (C) and the float ball filter support frame (E).
Empty the recovery tank with the drain hose (15).
5.
If necessary, follow the symbols "OPEN" and "CLOSE" as
shown in Figure 23 to open the bottom cover (F) of float
ball filter and then clean the float ball (D), filter support
frame (E) and filter sponge (I). After cleaning, fix the float
ball (D) into the filter support frame (E) and then align
the mark groove (L) of the bottom cap (F) of the float ball
filter with the mark groove (L) of the float filter support
frame (E). Screw the bottom cap of the float ball filter
tight, and fix the filter sponge (I) onto the float filter
support frame (E). Finally, connect it to the sewage
suction hose (M).
6.
Inspect the integrity of the tank sealing strip.
NOTE
Tank sealing strip (G) makes to produce the vacuum inside the tank when suction motor works. The
tank must be sealed can effectively absorb the water from the ground to recovery tank.
7.
Check whether the contact surface of sealing strip (G) is integrity and sealing is sufficient. If necessary, take the
sealing strip of the tank out of the groove (H) and replace it. Assembly the new sealing strip as shown in Figure 23,
the joint should be back in the middle area.