GB
FP
• Prohibited: manipulation, inappropriate
use, temporary repairs, use of other ener-
gy sources, removal or use of damaged
safety equipment, operating a leaking or
malfunctioning system, use of non-original
spare parts, exceeding the permitted
working pressure specified (max. + 10%),
working without protective equipment,
transporting / maintaining / repairing or
leaving a pressurised machine unattended,
using other / unsuitable lubricants, smok-
ing, naked flames, removing stickers.
• Prohibited: triggering in open spaces; us-
ing kinked / damaged grease hoses; hold-
ing the claw coupling closed; incorrect
disposal of leftover materials / cleaning
agents.
• Prohibited: Use in medical / food indus-
try; incorrect processing equipment; spark
formation.
2.4
Commissioning
Before start-up:
1. Observe technical data, figures, item
numbers, intended use and safety in-
structions
(see Instruction manual, Part 1, Chap-
ter: "Technical data" and the "Intended
use" chapter).
2. Carry out a visual inspection.
3. Do not use below 5° C.
Filling with grease cartridges or with
loose grease via grease pump:
Grease cartridges:
1. Install grease hose (item 04) on grease
gun and tighten using spanner wrench.
2. Unscrew the grease reservoir (item 05).
3. Open the cartridge at the slide-in open-
ing.
4. Push the cartridge over the grease piston
with a rotational movement (Figure 2a).
II/ 8
5. Pull back the handle piece (item 07) and
the grease cartridge as far as they will go
and secure them in place using the safe-
ty lever (item 08).
6. Open the cartridge.
7. Screw on the grease reservoir (item 05)
(Figure 2b).
8. Push the safety lever (item 08) and
press the handle piece into the grease
reservoir.
Loose grease via grease pump:
1. Install grease hose (item 04) on grease
gun and tighten using spanner wrench.
2. Pull back the handle piece (item 07) on
the installed grease reservoir (Pos. 05)
as far as it will go and secure it in place
using the safety lever (item 08).
3. Connect the filling hose of the grease
pump at the filling nipple (item 06) and
connect the grease reservoir.
4. Disconnect the filling hose of the grease
pump.
5. Push the safety lever (item 08) and
press the handle pieces into the grease
reservoir.
Compressed air connection:
1. Install an upstream maintenance unit
with filter pressure reducer and mist oil-
er.
2. Press the quick-action coupling of the air
hose onto the plug nipple (item 01)
(Figure 1a).
Operation:
1. Vent the grease gun by pressing the
venting valve (item 03).
2. Press the claw coupling of the grease
hose (item 04) on to the grease nipple
and hold it tightly during the filling pro-
cess.
3. Press the trigger lever (item 02).