1.8 TEMPERATURE OFFSET

If the heater is installed is a specially warm or cold location and this position cannot be changed because of the wiring
installation, the measured/onscreen indicated temperature can be adjusted by ±3ºC.
It may be useful if the temperature reading coincides with a nearby precision thermometer and the adjustment can be made
between -7ºC and +7ºC in 0.1ºC steps.
1. Switch the heater off by pressing the
2. Press the
key for two seconds and "0.0º" will be displayed.
3. Use the
or
key to indicate the temperature difference between the actual temperature and that displayed
onscreen. For example:
- Actual temperature measured in the room with a precision thermometer: 22ºC
- Selected temperature (onscreen) on the heater, when stabilised: 20ºC
- The difference is 22 - 20 = 2ºC. The value to enter is + 2ºC
4. To end, press the
key.
5. Switch the heater on again by pressing the

1.9 STAND-BY MODE

Press the
key. All the programming parameters will be saved in this mode.
The clock will remain onscreen, for example, "06:08".

1.10 SWITCH THE HEATER OFF OF A POWER SUPPLY SOCKET

- Activate Stand-by Mode (Point 1.9)
- Press the switch on the right at the rear and the screen will switch off.
- Remove the plug from the socket. If the switch-off time exceeds four hours, the current day and time must be programmed.

2. INSTRUCTIONS FOR THE INSTALLATION

The heater must not be installed just underneath a mains socket.
The heater must never be installed in a bathroom in a position in which the switches or other controls can be touched by a
person in the bath or shower.
The RCWave heater operates by natural air convection. In order to achieve correct performance with uniform heat distribution,
when installed on a wall, the lower part of the heater must a minimum of 10 cm and a maximum of 30 cm from the floor.
There must be a minimum distance of 15 cm from any wall or object (furniture and curtains etc), both to the sides and
above, to ensure adequate heating performance.