▷ Select
4 (TI-Forms)
in the Ceramill Motion Soft-
ware and confirm with
Fig. 7
The machine picks up the tool from location 1
and advances to the home position.
The machine is now prepared for the calibration-
milling process.
C A L I B R A T I N G T H E B L A N K H O L D E R
OK
.
3.3
Calibration process
The calibration process can only be per-
formed once per calibration sleeve. Should
errors occur during the process, we rec-
ommend replacing the calibration sleeve
(see chapter 3.4 on page 27) and starting
the process from the beginning.
The calibration process consists of 3 steps that
must be preformed one after the other.
1. Milling the measuring surfaces
2. Measuring the measuring surfaces (e.g. with the
caliper in the delivery scope of the Ceramill
Motion 2)
3. Performing the calibration milling