Operating the MagicSafe MSG150
9
Operating the MagicSafe MSG150
To avoid false alarms caused by cooking, using deodorants, heavy smoking and alcohol
consumption, the vehicle should be ventilated thoroughly before retiring to bed and then
the gas detector should be switched on.
No. in
fig. 8,
description
page 5
1
Green LED
The green LED flashes for approx. 10 minutes after the gas detector
has been connected to a voltage supply or switched on with the
RV-AMP-SW auxiliary switch. While the LED is flashing, the sensor is
brought to the operating temperature.
When the green LED glows constantly, the gas detector is ready for
operation.
2
Orange LED:
The orange LED glows if a fault occurs.
3
Red LED (alarm)
The red LED flashes if an alarm has been triggered.
In addition to this, a siren sounds an alarm signal.
(See also chapter "Alarm" on page 29.)
4
Pushbutton
This pushbutton is a test button and also mutes the system.
Test pushbutton
➤ Press this pushbutton once a month or after extended periods of
✓ The orange and red LEDs flash and a siren sounds.
Mute switch
➤ Press this pushbutton if you wish to switch off the sound during an
✓ The red LED continues flashing and a brief signal sounds every 45
Switching on the MSG150 as a single device or in combination with the external
siren (item no. 9101600008)
➤ Insert the 12/24 Vg plug in a socket or switch on the gas detector with the
RV-AMP-SW auxiliary switch.
✓ An acoustic signal sounds and the green LED (fig. 8 1, page 5) flashes for approx.
10 minutes.
During this time the gas detector conducts a system test and the sensor is brought to
operating temperature.
28
disuse to check the system is functioning.
alarm.
seconds. Then the system is armed again.
MagicSafe MSG150
EN