The control unit alignment takes approximately 12 seconds and signal tones sound during the
process. Then a full flush will occur and the electronic urinal will be ready for use.

4.2 Resetting the system (S5)

If you reset the system, the chosen programmes and settings are reset. Then you will be able to
select programmes and settings again.
Refer to page 2 for a diagram showing the signal sequence.
> Hold the magnetic key in front of the right-hand sensor.
Within approx. 3 seconds, several short signals will sound. Then 7 long signals will sound with
a longer pause of approx. 6 seconds between the 5th and 6th signal tone and the 6th and 7th
signal tone.
> Remove the magnetic key.
2 short signal tones will sound and then service programme S5 will be selected.
> Within 4 seconds, hold the magnetic key in front of the right-hand sensor again.
2 short signal tones will sound to confirm the reset.
> Remove the magnetic key.
Factory settings are active.

5. Operation

5.1 Selecting the flushing programmes

Refer to page 2 for a diagram showing the signal sequence.
Selecting Standard (P1)
> Hold the magnetic key in front of the right-hand sensor.
Within approx. 3 seconds, several short signals will sound. Then 3 long signals will sound.
> Remove the magnetic key.
2 short signal tones will sound and then flushing programme P1 will be selected.
Selecting Vario (P2)
> Hold the magnetic key in front of the right-hand sensor.
Within approx. 3 seconds, several short signals will sound. Then 4 long signals will sound.
> Remove the magnetic key.
2 short signal tones will sound and then flushing programme P2 will be selected.

5.2 Setting the flush duration (S4)

> Hold the magnetic key in front of the right-hand sensor.
Within approx. 3 seconds, several short signals will sound. Then 6 long signals will sound with
a longer signal tone and the 6th and 7th signal tone.
> Remove the magnetic key.
2 short signal tones will sound and then service programme S3 will be selected.
> Within 4 seconds, hold the magnetic key in front of the right-hand sensor again.
Flushing starts and, at the same time, a signal tone sounds at one-second intervals.
> Hold the magnetic key in front of the right-hand sensor until the desired flush duration is set.
Do this for a minimum of 5 seconds and a maximum of 20 seconds.
> Remove the magnetic key.
2 short signal tones will sound to confirm the set flush duration. Then the selected flushing
programme will be reactivated.

6. Cleaning and care

In order to clean the electronic urinal, the flushing programme is deactivated. 2  service pro-
grammes are available for this (see chapter 3.6). Refer to page 2 for a diagram showing the signal
sequence.
Read the care instructions for information on how to clean and care for the surface of the elec-
tronic urinal (see www.duravit.com).
19
Tabla de contenido
loading