necessary (Fig.7A - Fig.7B).
Important: if there is an oven under the induction hob it is
advisable for it to have a cooling fan. Do not use the induction
hob while PYROLITIC cleaning is in process.
Warning: to allow the circulation of as much fresh air as nec-
essary, there must be at least 40 mm between the induction
hob module and any appliance installed under it (Fig.7B). In
any event, adequate aeration must be provided. To allow fresh
air circulation there must be openings in the kitchen furniture
(Fig.6A - Fig.7A) of the sizes indicated in Fig.6B - Fig.7B.
Electrical connections (Fig.2B):
Before making the electrical connections, check that:
- the ground cable is 2 cm longer than the other cables;
- the system ratings meet the ratings indicated on the identi-
fication plate fixed on the lower part of the worktop;
- the system is fitted with efficient earthing compliant to the
laws and regulations in force.
If the appliance is not fitted with a cable, use type:
"H05V2V2-F" for a power level of up to 6400 Watts. The
cross-section of the cable should be at least 2.5 mm², or 4
mm² for greater power levels. The cable should never reach
a temperature which is 50°C above the temperature of the
room in which it is installed. The appliance is designed for
permanent connection to the electricity supply and should
therefore be fitted with an omnipolar switch which has a mini-
mum opening of 3 mm between contacts. The switch should
be suitable for the charge indicated on the appliance data
plate and must conform to all current legislation (the yellow/
green earth wire must not be interrupted by the switch). The
omnipolar switch must be easy to reach once the installation
process has been completed.
USE AND MAINTENANCE
Use (Fig.2):
A = ON/OFF Button
B = Key Button
C = ON/OFF indicator key button
D1 = Slider Control
D2 = Cooking level indicator
E = Cooking zone selection button
I = Residual heat symbol "H"
L1 = Quick Heat Function (Heat up) ON/OFF button
N = Timer Buttons
N1 = Tenths display
N2 = Units display
O = Hob indicator with timer function active
Q = Timerz Display
R = Cooking zone display
R1 = Active cooking zone indicator
S = Booster
- To start the hob, press the button (A), on all displays (R) the
zeros will appear for 20 seconds with flashing decimal points.
If no operation is performed within this time period, the hob
switches off.
- It is possible to switch a cooking zone on by selecting one of
the 4 buttons (E). The cooking zone is active when the decimal
point becomes fixed.
Set the desired cooking level by acting on the SLIDER
control (D1).
Note: to set the cooking level, just slide your finger over
the SLIDER control (D1).
From Left to Right the temperature level is increased (D2)
from 1 to 9. To decrease just perform the operation in the
reverse order.
The cooking level (e.g. 6) will appear on the cooking zone
display (R).
Note: you may also directly press any point on the SLIDER
control without running your finger along it; in this case the
temperature level corresponding to the point at which the
control was touched will be activated directly.
- To select the double cooking zone, where applicable, first
press button (E), then adjust the cooking level (D1) and press
the double zone selector button (F).
To deactivate the double zone, press button (E) followed
by button (F).
- There are several different ways of switching off a cooking
zone:
1- Select it and run your finger over the SLIDER control until
you reach "0".
2- Select it and directly press the "-" symbol on the SLIDER
control.
- When a cooking zone (E) is switched to the OFF setting
and the temperature of the glass surface remains above ap-
proximately 50°, the display (R) corresponding to that zone
will show a luminous signal alternating between "0" and "H".
If the hob is switched to the OFF setting (A), the luminous
signal will display the letter "H" in a fixed manner.
Warning: to prevent damage being inflicted on the electronic
circuits, the hob is fitted with an overheating safety system. In
situations where the appliance is used at high power levels for
a prolonged period of time, the hob may switchoff one or more
of the activated zones temporarily, until the temperatures
return to the set levels. On the display corresponding to the
cooking zone which has been temporarily switched off, the
power level will be shown in alternation with a E/4. This will
stop flashing once the cooking zone has beenreactivated.
Lock function (Fig.2 - (B)):
To prevent the hob from being used by children, all functions
may be locked by pressing the Lock button (B); this function
is active when the indicator light (C) is illuminated.
- To activate or deactivate it, press and hold button (B) for
approximately two seconds.
- If the hob is switched on and the Lock function is enabled,
button A will still work.
Magnetic sensor (Fig.2 - (I)):
- The hob is equipped with a pan sensor; when the pan is
removed or badly positioned, the
If, on the other hand, the surface of the glass is still hot, the
symbol will appear alternating with the
O.S.D. (Overflow Safety Device) (Fig.2):
The hob is equipped with a safety system which moves all
hotplates to the OFF position and activates the safety lock
when liquids or items are detected on the control panel A.
These symbols will flash on the display:
They can be deactivated by removing the item or the liquid.
The hob will switch off automatically.
Attention!
When the hob switches on, the timer display Q stays on at the
value
If the function is not activated, after a few seconds
the display Q shows nothing.
Timer (Fig.2 - (Q)):
Note: the Timer can be activated on all 4 cooking zones at
- 23 -
symbol will appear.
.
.