1.2 Nemolink Evopool
functions
Filtration Plus:
System which achieves filtration optimisa-
tion to increase efficiency, with the result-
ing electricity saving, while adding a cycle
to increase the effectiveness of pool sur-
face cleaning.
EFFECTIVENESS: work cycles specially developed
for use in pools achieve maximum effectiveness.
SAVINGS: a minimum of 80% electricity savings over
standard pumps, with the resulting cost savings.
Backwash Plus:
Backwash system which, thanks to a spe-
cially developed cycle, increases process
efficiency while shortening cleaning time,
drastically reducing the amount of water
used for efficient cleaning.
EFFECTIVENESS: reduction of backwash time and
improved filter-cleaning efficiency.
SAVINGS: a minimum of 25% water savings over
standard pumps.
Filterwatch:
The rotational speed of the pump automatically adapts
to the normal and progressive clogging of the filter so
as not to reduce the effectiveness of the Filtration Plus
function.

2. HANDLING

It is supplied in suitable packaging to prevent it deteri-
orating during transport. Before unpacking the product,
check that the packaging has not suffered damage or
is misshapen.
Handle the product carefully, with the right tools.

3. INSTALLATION

This equipment is designed for use indoors.
3.1. Pump installation.
WARNING: Follow the installation manual in-
structions for the standard pump.

3.2. Electrical connection

The electrical installation must have a multiple
separation system with a 3 mm contact opening.
The system's protection will be based on a dif-
ferential switch (∆fn = 30 mA).
The equipment is supplied with a power cable with plug.
Do not manipulate the equipment.
3.3 ControlSystem
ControlSystem installation
ControlSystem
ControlSystem
Fit the ControlSystem to the multiport filter valve con-
trol. (See figure 1)
• Select a location as near as possible to the turning
centre.
• Clean the surface with alcohol.
• Lift
the
protective
ControlSystem into the chosen place.
• Watch the "ControlSystem" position. Screw area
should be closer to the rotation axis.
• Secure the assembly by tightening the tape under
the control. Check that it is fixed properly.

4. START-UP

4.1 Starting up the equipment.
Follow the installation manual instructions for the
pump to start it up properly.

4.2. Initial configuration

The first time you start it up you need to link Nemolink
with ControlSystem (See figure 2)
WARNING: It is very important to follow the or-
der of the operations described here:
4.2.1 Starting up the Evopool
• Connect the Nemolink pump to the power supply.
The system will start up and a set of lights indicates
that it has been activated.
If a ControlSystem has not already been linked to it,
the pump will not start up. Nemolink
is on standby waiting for the link to be estab-
lished. The 3 leds flash together.
4.2.2 Activating the ControlSystem
To prevent the battery running out before the equip-
ment is started up, the ControlSystem has an internal
ON/OFF switch that must be activated (See figure 2)
CAUTION: Do not approach magnetic elements
to ControlSystem during this operation.
Ensure that no magnetic fields can affect the
proper operation of the system.
WITH
THE
PUMP
ELECTRICAL CURRENT (see 4.2.1):
• Make sure the valve is in the intermediate position
between 1 and 4
• Lift the cover, loosening the screw.
• Activate the ControlSystem by moving the mini-
switch to the "ON" position.
When the battery is connected, ControlSystem trans-
mits a unique code for an interference-free link.
Flashing leds indicate that proper communication has
been achieved. The green LED will light.
Replace the cover and fix it with the screw.
Torque: 0.2 Nm.
10
EN
stickers
and
plug
CONNECTED
TO
the
THE