(*) Possible causes of error for malfunction (status LED flashes red):
Malfunctions must always be acknowledged by unplugging the plug and can be triggered, for example, by
the following causes:
The plug was not plugged in correctly; interlocking therefore not possible => plug in the plug quickly.
The plug was unplugged during the charging procedure:
The plug was not locked correctly – unplug the plug and plug in correctly and make sure it interlocks
correctly.
The plug on the charging station supplies an invalid state:
Cable hardware fault – unplug the plug and plug it in correctly, replace the cable if necessary.
Temperature shut-off: The permitted temperature in the charging station was exceeded – unplug the
plug and wait until the charging station has cooled down.
Resetting an fault:
If an interruption occurs during the plugging-in or charging procedure, the charging station will attempt to au-
tomatically restart the procedure (max. 5 times).
If the charging procedure is not able to be started, this must be confirmed by properly ending the charging
procedure (see Chapter
untraceable fault occurs repeatedly, please contact your service partner.
24/172
Troubleshooting
"2 Using the charging
station") or possibly by restarting the charging station. If an