4
Troubleshooting
PROBLEM
Status LED does not light up
Charging procedure is not
started
The vehicle not fully charged
Increased charging time
Standard plug cannot be un-
plugged
Status LED flashes red
For more information, please refer to the FAQ list at www.kecontact.com.
Troubleshooting
Possible causes
No voltage supply – check the FI circuit breaker and circuit line
breaker and switch on, if necessary.
Defective – please contact your service partner.
The plug was not plugged in correctly – unplug and plug in con-
nector again.
The charging procedure was not performed correctly – follow the
instructions in Chapter
The plug may possibly be dirty in the locking area or damaged –
clean the plug or have it replaced.
The vehicle does not require energy or it has a fault – check vehi-
cle.
The vehicle is programmed to charge at a later starting time.
Power reduction due to excessive temperature by the vehicle or
the charging station:
- Protect the vehicle and the charging station from direct sunlight
during the charging procedure (carport, garage,...)
- Visual inspection of the plug and socket device to see if it is dirty,
worn or damaged.
Contact your service partner, if necessary.
No enable due to external control device (energy supplier, photo-
voltaic system etc.)
The charging procedure was not ended correctly by the vehicle –
end the charging procedure according to the instructions of the ve-
hicle manufacturer.
The plug may possibly not be able to be unlocked under tension –
press the plug in and connect to vehicle again. Then end the
charging procedure again.
Malfunction – first check the possible causes of error for the mal-
function (*).
Switch off the supply voltage of the charging station (installed or
superordinate FI circuit breaker and line circuit breaker). Unplug
the charging cable from the charging station. Switch on the voltage
supply again.
Defective – please contact your service partner.
"2 Using the charging
station".
23/172