AC401 USA 3 langue mars2011_AC401inter 042008 12-01-25 11:12 AM Page 11
STEP 7
OUT OF RANGE INDICATOR
STEP 8
MICROPHONE SENSITIVITY
STEP 9
ALARMS AND VIBRATION (VIBRATION NOT AVAILABLE IN SOME COUNTRIES)
STEP 10
ROOM TEMPERATURE CONTROL
Your monitor is equiped with an optional "Out of range" indicator function, which will advise
you when the two units are not communicating with each other. Out of range situations can
be caused by distance or by physical interferences.
Range: up to 250 meters/ 820 ft (open field); between 80 meters/ 262 ft and 100 meters/328
ft (indoors).
When the units are out of range you will hear a DOUBLE BEEP every 8 seconds and the "out
of range"icon will flash on the screen of the parents unit.
• Press MENU, the OUT OF RANGE icon and the word ON will appear on the screen.
• Turn this function ON or OFF by using the arrows.
• Press SELECT
• Press MENU to view the next option, or EXIT if you wish to stop programming now.
The sound monitoring can be "voice activated" or "continuous". If you choose the continuous
transmission mode, you will hear your baby's every little sounds. If you use "voice activated"
you will hear sounds depending on the level of sensitivity that you choose.
• Press MENU, the MICROPHONE and the word ON will appear on the screen.
• Leave it ON to keep it "voice activated" or OFF to be in "continuous" mode. Use the arrows
to select On or OFF.
• Press SELECT.
• If you wish to use the voice activated monitoring function, Press MENU again to chose the
level of sensitivity of the microphone (4 levels), using the arrows.
• Press SELECT when the desired level appears on the screen.
• Press MENU to view the next option, or EXIT if you wish to stop programming now.
This menu will appear ONLY if the vibration option is available on your unit. It allows you to
choose between the following notification options :
1. Alarm only
2. Vibration only
3. Alarm and vibration
If selected, the vibration will work for the following alarm functions: 1) when the units are
out of range (if out of range function activated); 2) when minimum or maximum temperature
level is reached (if this function is activated); 3) when there is no movement for 20 seconds
(if movement function is activated)
NOTE : The vibration mode will not work when the batteries are low or if the parents unit
is on the charger.
• Press MENU and choose the desired option. The wave icon is for the vibrationmode and
the bell icon is for the alarm mode.
• Select the desired option, using the arrows. Press SELECT.
• Press MENU to view the next option, or EXIT if you wish to stop programming now.
Your Angelcare© monitor can also monitor your baby's room temperature and let you know
when the temperature is too high or too low. A triple BEEP will be heard if the temperature
reaches levels out of the chosen range.
• Press MENU, the snow flake and sun icons and the word OFF will appear on the screen.
• Turn it ON or OFF using the arrows.
• Press SELECT.
• If you select to have the room temperature control ON, Press MENU.
The SNOW FLAKE icon will appear, with the temperature. Select the desired lowest
temperature with the arrows and press SELECT.
• Press MENU. The SUN icon will appear, with the temperature. Select the desired highest
temperature with the arrows and press SELECT.
• Press EXIT as this was the last available programmable function.
11