Operational Summary - Nikon Laser 550A S Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Operational Summary

Caution—use of controls or adjustments or
Jp
performance of procedures other than those
En
specified herein may result in hazardous radiation
Fr
exposure
Es
1. Install a battery in the battery chamber. (See "Changing
Batteries")
Pt
2. Rubber eyepiece cup
Both eyeglass wearers and non-wearers can use this
rangefinder without attaching the rubber eyepiece cup.
3. Diopter adjustment
Adjust diopter to obtain a clear image in the LCD.
First, rotate the diopter adjustment ring counterclockwise
until it comes to a complete stop. Next, turn on the power
to activate the LCD when you look through the Nikon Laser
550A S. Rotate the diopter adjustment ring clockwise until
the display comes into focus.
If the diopter is not adjusted to correspond to your
eyesight, you may not be able to clearly focus your subject.
4. Measuring
Note: See the chapter "External and Internal display" for external
LCD panel.
Note: Depressing and holding down the POWER button causes
all symbols to be displayed in the internal LCD panel. After
you remove your finger from the POWER button, the last-
used setting is displayed. (If you briefly press the POWER
button then remove your finger, the LCD panel may
display the last-used setting without displaying all of the
symbols. This is not a malfunction or other problem.)
Before measuring, be sure to confirm settings, such as unit,
measurement/display mode and priority mode.
: See the relevant mode section in this manual for setting.
42
Set FULL/Limited
measurement mode
POWER
LCD is illuminated
Set your desired modes
Align the reticle
with the target
For continuous distance
and angle measurement
(up to 20 seconds), keep
POWER
button depressed.
appears
or
MODE
Indication
Results are converted
remains
to the mode set and
illuminated for
displayed.
30 sec.
30 seconds pass without operation *
Power off: LCD indications disappear
※ See the the chapter "External and Internal display" for details
regarding the operations and results display of the various
modes."
* Power turns off 30 seconds after the last operation.
☆【Continuous measurement mode】
Keeping the POWER button depressed allows you to
perform continuous measurement for 20 seconds.
Blinks while performing measurements.
When measuring a pin at a golf course, for example, use First
Target Priority and Continuous measurement mode for easy
measurement. With no objects between you and the pin, the
smallest number is the distance to your targeted pin.
5. Selecting display unit (Factory default setting is yard.)
Meter
Yard
[
]
[
]
1. Confirm the LCD panel is on.
2. Press and hold the
button for approx. two seconds.
3. When display unit has switched, release the
button.
4. After the unit is set, results will be converted and displayed in
the your selected measurement unit.
6. Switching measurement/display modes (Factory default
setting is linear distance measurement mode)
Linear Distance [
]
Horizontal Distance [
Height [
]
Angle [
]
Vertical Separation
between 2 points
[
]
point
By pressing the MODE button, modes will change in the order
indicated above.
The angles and heights of two points are displayed only at the
full-mode setting.
1. Confirm the LCD panel is on.
2. Press
button within 0.5 seconds.
3. Release
button to switch the mode.
4. Repeat steps 2 and 3 until your desire mode is displayed.
5. Switching the mode after measurement converts the
results to the new mode.
6. After the mode is set, measurements are performed in the
new mode.
7. Switching Full/Limited modes (default setting is limited
mode)
1. Confirm the power is off (LCD is off ).
2. Press and hold
button, then depress and hold
button within 0.5 second.
3. Continue to press and hold both buttons, (more than 2
seconds),to confirm the internal display is on.
When these buttons are pressed, all symbols are displayed .
Jp
En
Fr
]
Es
Pt
43