2. CONFIGURATION
To adapt the Dynamometer 04 to different use conditions, it's possible to configure the main parameters. It's possible to select:
UNIT OF MEASURE : Kilo [Kg], Ton ( t ), Short-ton [ton], Pounds [lbs], DecaNewton [daN], KiloNewton [kN].
UPDATE SPEED OF THE DISPLAY: 4 reading every sec, 2 every sec, 1 every sec, 1 every 2 sec, 1 every 4 sec, 1 every 8
sec, ( Default layout: 2 every second ).
POWER OFF : Enable ( after 20 minutes of inactivity), Disable.
Reading resolution: 1,2,5,10, 20,50 apart from the selected unit of measure (Default layout : 2 ).
3.1 ACCESS TO THE CONFIGURATION MENU
You can enter the configuration menu by pushing " TARE " and " PEAK " at the same time; with the buttons TARE
used individually you can select the heading to modify and by pushing " HOLD "
menu.
3.2 LAYOUT OF THE UNIT OF MEASURE.
Enter the configuration menu as described above; with the buttons or select the heading UNIT and push . The instrument will
display UNIT on the upper part of the display while on the lower the current unit of measure is visualized. Select the unit with the
buttons or and confirm by pushing : " OK " will be visualized for some seconds and then you can come back to the first
configuration menu: push the buttons and at the same time to come back to the normal running.
Conf
UNIT
ON
PEAK
TARE
OFF
3.3 LAYOUT OF THE UP DATE READING SPEED
Enter the configuration menu as described in 3.1; with the buttons or select the heading RATE and
push ; the instrument will display rAtE on the upper part of the display while on the lower the current
update speed is visualized. Select the unit with the buttons or and confirm by pushing : " OK " will be
visualized for some seconds and then you can come back to the first configuration menu; push the buttons
and at the same time to come back to the normal running.
N.B. the update speed directly affect the battery consumption.
Conf
RATE
ON
TARE
PEAK
OFF
0
kg
ON
TARE
PEAK
HOLD
OFF
Unit
LBS
ON
TARE
HOLD
PEAK
OFF
rAtE
ON
PEAK
HOLD
TARE
OFF
Conf
UNIT
ON
TARE
PEAK
HOLD
OFF
Conf
UNIT
ON
TARE
HOLD
PEAK
OFF
Conf
RATE
ON
HOLD
PEAK
TARE
OFF
37
Unit
kg
ON
OFF TARE
PEAK
HOLD
you can enter the modification
LBS
ON
TARE
PEAK
HOLD
OFF
LBS
ON
HOLD
TARE
PEAK
OFF
or PEAK
0
HOLD
0
HOLD