HIKOKI RP 3608DA Instrucciones De Manejo página 16

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 62
English
TROUBLESHOOTING
Use the inspections in the table below if the tool does not operate normally. If this does not remedy the problem, consult
your dealer or the HiKOKI Authorized Service Center.
1. Power tool
Symptom
Tool doesn't run
Suction power is weak.
Fails to suck in dust.
Dust leaks from the vent.
Tool suddenly stopped
Attachments such as the
connection adapter or joint
-can't be attached
-fall off
Battery cannot be installed Attempting to install a battery other than
Possible cause
No remaining battery power
Battery isn't fully installed.
Concrete dust is accumulated on the
terminals of the battery installation
compartment as well as on the battery
sliding grooves.
The tank is full of dust or water.
Filter is clogged.
The fi lter is not installed.
(Not set in place)
Plastic bag is incorrectly installed.
Filter is not installed.
Filter is improperly installed.
Filter is damaged.
Tool was overburdened
The battery and/or the unit is overheated.
The shape or the dimensions of an
attachment part does not match.
that specifi ed for the tool.
Charge the battery.
Push in the battery until a click is heard.
Clean off the accumulated concrete dust
with a dry cloth.
Dispose of the dust or water.
After that, remove any dust attached to
the fi lter.
Conduct air blow dusting or remove the
dust attached to the fi lter.
Check to see if the fi lter is properly set.
Properly install the plastic bag.
Properly install the fi lter.
Replace the damaged fi lter.
Get rid of the problem causing the
overburden.
Let the battery and/or the unit cool down.
Check the model in use and make sure
to use the designated accessories and
attachments listed in this document or in
our catalogue.
Please install a multi volt type battery.