eNet
Regulador fluorescencia vía radio 1-10 V
Switchoff warning
Priority, lockout protection
Priority, restraint
Priority, wind alarm
Priority, sun protection
Priority, twilight
Switch off brightness overs
hoot
82581013
J:0082581013
On, Off
Basic setting: Off
0...4
Basic setting: 1
0...4
Basic setting: 2
0...4
Basic setting: 3
0...4
Basic setting: 0
0...4
Basic setting: 0
On, Off
Basic setting: On
9/11
If the switchoff warning is ac
tive, then, during switchoff,
the systems dims to minimum
brightness within 30 seconds
and only then switches off. If
the parameter "Dim down
ramp" is configured as longer
than 30 s, then the length of
the dim down ramp is applied.
If, during the dim down opera
tion, another command is gi
ven, e.g. switch on or scene
recall, then the switchoff war
ning stops and the command
is executed. A switchoff com
mand restarts the time for the
switchoff warning.
Note: The set time apply to
operation using radio transmit
ters. The device is switched
immediately when the Prog
button is pressed.
Specifies the priority for reca
lling and removing a scene of
type Lockout protection for
the channel.
Note: 1 is the highest priority
and 4 the lowest. 0 means no
priority.
Specifies the priority for reca
lling and removing a scene of
type Forced position for the
channel.
Specifies the priority for reca
lling and removing a scene of
type Wind alarm for the chan
nel.
Specifies the priority for reca
lling and removing a scene of
type Sun protection for the
channel.
Specifies the priority for reca
lling and removing a scene of
type Twilight for the channel.
Allows automatic switchoff
according to the brightness. If
the parameter is On, then the
light controller switches off au
tomatically when the bright
ness setpoint is greatly excee
ded.
Note: This parameter is not
yet active, as a light controller
has not yet been implemen
ted.
13.03.2014