eNet
Tecla sensora eNet con receptor vía radio
Settings window
Device settings
Parameters
Manual commissioning
Allow extension unit operation On, Off
Settings, channel
Parameters
Manual commissioning
Operating mode
Local Operation
Manual switch-off of the run-
on time
32582713
J0082582713
Setting options, Basic set
ting
On, Off
Basic setting: On
Basic setting: On
Setting options, Basic set
ting
On, Off
Basic setting: On
Normal operation
Continuous on
Continuous off
Basic setting: Normal Opera-
tion
On, Off
Basic setting: On
On, Off
Basic setting: Off
5/10
Explanations
Blocks manual commissioning
for the device channel.
Note: In the "Off" setting, the
device cannot be reset to the
factory setting.
Prevents operation via wired
extensions.
Explanations
Blocks manual commissioning
for the device channel.
Note: In the "Off" setting, the
device cannot be reset to the
factory setting.
Normal operation
The output can be operated
with radio transmitters, with
the button and with a connec-
ted extension.
Continuous on
The output switches to conti-
nuously "On". All operations of
radio transmitters, of the but-
ton and of connected exten-
sions are ignored.
Continuous off
The output switches to conti-
nuously "Off". All operations of
radio transmitters, of the but-
ton and of connected exten-
sions are ignored.
Blocks the output for operation
using the button.
Allows manual switch-off of a
running run-on time. If the pa-
rameter is switched off, then a
switch-off command will also
switch the actuator on. This
parameter is directly connec-
ted to the "Run-on time" para-
meter.
15.07.2016