Anleitung_NPTP_E_5000_SPK7__ 08.06.15 08:07 Seite 11
10. Troubleshooting guide
Faults
The equipment does not start
The equipment does not pump
Insufficient pumping rate
The equipment switches off after
briefly running
Cause
- Power supply not connected
- Intake sieve clogged
- Discharge hose kinked
- Intake sieve clogged
- Performance reduced due to
heavily contaminated and
abrasive water impurities
- Motor circuit-breaker switches the
equipment off due to excessive
water contamination
- Water temperature too high;
motor circuit-breaker switches
the equipment off
GB
Remedy
- Check the power supply
- Clean the intake sieve with a
water jet
- Unkink the hose
- Clean the intake sieve
- Clean the equipment and replace
wear parts
- Pull out the power plug and clean
the equipment and shaft
- Ensure that the maximum
permissible water temperature
(35 °C) is not exceeded
11