KCH-240
Hydraulic Cable Cutter
MAINTENANCE AND SERVICING
Damaged equipment can fail, causing serious personal injury. do not use damaged
equipment. If abnormal noise or vibration occurs, have the problem corrected before
further use.
1.
BEFORE EACH USE, inspect the general condition of the tool. Check for loose
screws, misalignment or binding of moving parts, cracked or broken parts, and any other
condition that may affect its safe operation.
2.
AFTER USE, depress the release level to activate the piston to the end, clean
external surfaces of the tool with clean, moist, smear the rust preventing oil on the metal
surface of the tool and the dies to avoid rusty. Store the tool in the dry environment.
3.
Service to the tool should only be done by a qualified Service Technician.
4.
in order to prolong the life of the tool please change the oil per year. Make sure the
oil filtered by 120 mesh net or over 30µm strainer. Meantime avoid the dusty into the oil
cup.
5.
Pre-grinding, After a long time cutting, the blade will blunt, then you can use a
grinder to polish the surface to sharp.
HOW TO CHANGE THE OIL( Example for THS-150)
The dust or air inside the tool will damage the sealing kit so caused the tool lose
function. Make sure the oil is clear and no dust entering into oil when changing oil.
Wait for a while and exhaust the oil completely out of the oil tube before inserting the
oil plug.
Please lock the handle to avoid the air entering into hydraulic system when changing
oil.
Please wear the rubber gloves to avoid skin touching the oil directly, if touches it in
careless, please wash the skin by soap water in timely. In order to protect the
environment please drain the waste oil to the treatment center where was approved by
government.
5. If the tool not used for a long time, please make sure the piston stay on its original
position, Clear up the tool and paint the rustproof oil both to the tool and the die. Put them
back to box and store the tool in a dry surrounding.
6. The Sealing kit inside the tool will be abraded in some degree after using, when the oil
leaking a lot, please contact the distributor to replace the Sealing kit in timely.
TROUBLESHOOTING
FAULT
ANALYSIS
1. The pump lack oil
A. No pressure or the
2. There is dust exist in
pressure is not enough
oil
during operation
3. Inner leakage
SOLUTION
1. Fulfill or replace the oil
2. Change the oil
3. Contact manufacturer or
distributor
www.grupotemper.com