GPIO
BLS 2M and BLR 2 incorporate 4 GPI and 4 GPO each one. Therefore, the system can be
considered as bidirectional. When GPI contact is closed due to an external action, this state will
be reflected in the corresponding GPO in the other side.
For example, closing GPI number 1 in a BLR 2 ( the GPO number 1 in BLS 2M will receive
the state and will close its contact. The system works in the same way in the other sense.
WEBSERVER
For advanced setup you need to access to webser on each device. Inside this interface it is
possible to find all information about connection device and to set some features like name, audio
source, sending codification, etc.
1
. In your browse type the next URL according to the device:
bls_2.local/
bls_2m.local/
bls_2_lite.local/
NOTE: Take into account that these are the default names and must be typed the first time. If you
change the name, you must write the new name in order to access.
(xxxxxxxx.local/).
NOTE: In case your PC was in the same range, it is also possible to access using the IP address.
BlueLine System
INSTALLATION
blr_2.local/
blr_2_lite.local/
blr_2a.local/
- 9 -