Reset to Factory Default Settings

If the encoder no longer functions as expected, you can choose to
restore the encoder to its factory default settings.
Use the firmware revert button to reset the encoder.
Figure: Firmware revert microswitch location on the rear of the
encoder
1.
Disconnect power from the encoder.
2.
Using a straightened paperclip or similar tool, gently press
and hold the firmware revert microswitch.
3.
While continuing to hold the microswitch, power the
device. Release the microswitch after three seconds.
Caution — Do not apply excessive force. Inserting the tool
too far will damage the device.