If there is any risk of freezing, open the hopper plug, disconnect
the pipelines and drain all water from the circuit (fig.9).
- Before opening the drain plug or the grid, ensure
that the main switch is turned to 0 and the plug is
disconnected from the power supply.
14. MAINTENANCE
- Maintenance must be performed by adequately
trained personnel, after switching off the machine,
disconnecting it from the power supply and emptying
the hopper.
Check weekly that the compressor air filter is clean. If
deteriorated, replace.
Check weekly that the electric motors are free of dust and dirt
and if necessary clean using compressed air.
Check weekly that the plug and socket contacts are clean, dry
and rust free.
Every six months arrange for an inspection of the machine by
an authorised IMER service centre.
- Spent oil is a special waste. Therefore it must be
disposed of according to current legislation.
- Always keep notices and symbols on the machine
legible.
15. REPAIRS
- Never start up the mortar mixer during repairs.
Repairs to the electrical installation must be performed
exclusively by specialised personnel.
Use exclusively original IMER spare parts; modifications
to parts are strictly prohibited.
- If any guards are removed for repairs, ensure they
are refitted correctly at the end of work.
IMER INTERNATIONAL S.p.A.
IMER MORTAR MIXERS
FIG.9
25