User Programming Mode - Pentair SOFTFLO 5600 Manual De Servicio

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

USER PROGRAMMING MODE

User Programming Mode Options
Abbreviation
Parameter
DO
Day Override
RT
Regeneration
Time
H
Feed Water
Hardness
RC or SF
Reserve Capacity
CD
Current Day
NOTE: Some items may not be shown depending on timer
configuration. The timer will discard any changes and
exit User Mode if any button is not pressed for sixty
seconds.
User Programming Mode Steps
1. Press the Up and Down buttons for five seconds while in
service, and the time of day is NOT set to 12:01 PM.
2. Use this display to adjust the Day Override. This option
setting is identified by "DO" in the upper left hand corner of
the screen.
3. Press the Extra Cycle button. Use this display to adjust the
Regeneration Time. This option setting is identified by "RT"
in the upper left hand corner of the screen.
4. Press the Extra Cycle button. Use this display to adjust the
Feed Water Hardness. This option setting is identified by "H"
in the upper left hand corner of the screen.
Range: 1-199 hardness
5. Press the Extra Cycle button. Use this display to adjust the
Fixed Reserve Capacity. This option setting is identified by
"RC" or "SF" in the upper left-hand Corner of the screen.
Description
The timer's day override setting
The time of day that the system
will regenerate (meter delayed,
timeclock, and day-of-week
systems)
The hardness of the inlet water
- used to calculate system
capacity for metered systems
The fixed reserve capacity
The current day of week
6. Press the Extra Cycle button. Use this display to set the
Current Day of the Week. This option setting is identified by
"CD" in the upper left hand corner of the screen.
7. Press the Extra Cycle button to end User Programming
Mode.
PENTAIR SOFTFLO 5600 Service Manual • 15

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido