4.8.2 Reversed and Split Pair Fault

In the event of a Reversed Pair fault, the following is displayed:
In the event of a Split Pair fault, the following is displayed:
NOTE: For cables less than 6 ft (2m) in length the tester is unable to
distinguish a Split Pair condition.
In this event (cable too short), the following screen is displayed briefly,
before the screen to warn the user that a Split Pair test has not been car-
ried out.
16
ID1
4 5 1 2 3 6 7 8 S
FAILED
TIA568
L=94ft
Vp=71%
4 5 1 2 3 6 7 8 S
Reversed Pair
Pin 4 5
ID1
4 5 1 2 3 6 7 8 S
FAILED
TIA568
L=94ft
Vp=71%
4 5 1 2 3 6 7 8 S
Split Pair
Pin 1 2 3 6
* * * * * * * * * * * * * * * * * * *
Too Short for
Split Pair Test
* * * * * * * * * * * * * * * * * * *