Troubleshooting Guide - Intex ECO 7220 Manual Del Propietário

Ocultar thumbs Ver también para ECO 7220:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

(260IO) MODEL ECO 8220/8230 & 7220/7230 SALTWATER SYSTEM ENGLISH 7.5" X 10.3" PANTONE 295U 08/15/2014

TROUBLESHOOTING GUIDE

PROBLEM
• Insufficient operating hours of
INSUFFICIENT
the Saltwater System.
CHLORINE
• The salt level in the pool water
is less than 2000ppm. This is
insufficient.
• Chlorine loss due to intense
sunlight exposure.
• The bather load has increased.
• Clogged or dirty electrolytic cell.
• High UV level exposure.
• Excessive calcium hardness is
WHITE FLAKES IN
present in pool water.
THE WATER
• No power supply.
NO LED DISPLAY
• RCD has not reseted.
• A power fuse has blown.
• LED failure.
SAVE THESE INSTRUCTIONS
CAUSE
SOLUTION
• Increase the daily Saltwater System
operating time. See "Operating Instructions".
• Check the salt level with the Test Kit. Adjust
as needed. See "Salt & Pool Water Volumes".
• Use a pool cover when the pool is not
in use and/or when the unit is operating.
• Increase the daily Saltwater System
operating time. See "Operating Instructions".
• Remove the cell for inspection, clean it if
necessary. See "Maintenance".
• Cover the pool with a pool cover for 2
days with the device running and then
test the water using the test strips.
• If the pool is clean and clear, add stabilizer
to the water and then test the water with the
device running.
• Drain about 20 to 25% of the pool
water and add fresh water to decrease
the calcium hardness. Inspect the
electrolytic cell for scale buildup. Clean
the electrolytic cell if necessary.
• Plug the cell cord firmly into the cell
housing receptacle.
• Find out the switch and turn on.
• Reset the RCD.
• Contact Intex Service Center.
• Contact Intex Service Center.
260
English
A
Page 25
Tabla de contenido
loading

Este manual también es adecuado para:

Eco 8220Eco 7230Eco 8230