Comunello FAST 50/160 Manual De Instrucciones página 26

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
5.2
Electrical connection
Wire in the apparatus according to the electrical supply required by the actuator (see label on product),
following the table below.
0
Yellow/Green
1
Blue or Gray
2
Black
3
Brown
Pos.1
Pos.2
Pos.3
Pos.1
Pos.2
Pos.3
5.3
Operating test
Pos.1
Pos.2
Press the control button and close the window, checking that:
Pos.3
a.
The window is completely closed. If it is not, check that the gap between the window and the
Pos.1
frame is bigger than or equal to 0 mm. If necessary, insert spacers so as to obtain the correct gap.
Pos.2
b.
The spindle is perfectly perpendicular to the window frame. If necessary adjust the fixing bracket
Pos.3
by using the screws and slots.
Having reached the correct closing position, press the control button and open the window in order to check
that the actuator runs freely over the full travel set up.
Having achieved the required opening run, press the control button again to close the window. Once the window
has completely closed, check that the screws, supports and fixings are tightened correctly, and that the seals
are sufficiently compressed.
26
230VAC supply
Earth
Neutral / Common
Phase / Open
Phase /Closed
Electric 230VAC wiring
0
1
2
3
4
5
6
0
1
2
3
Installation completed
N
110/230V~ 50/60Hz F
4
4
5
5
6
6
N
110/230V~ 50/60Hz F
1
2
24 Vdc
4
4
4
5
5
5
6
6
6
1
2
24 Vdc
Tabla de contenido
loading

Tabla de contenido