Technical data

8.1 Technical data for the power supply

Power supplies must always be selected in such a way that ensures that the power require-
ment of the connected LED modules is covered and that the minimum power consumption
level is reached. The maximum connected load must not be exceeded.
Item No.
Power,
max. [W]
Connected
load, max. [W]
Power,
min. [W]
Output current,
max [A]
Dimensions
(L x W x H)
[mm]
Power factor
Power reserve,
min. [%]
Rated voltage,
primary side [V
AC]
Mains frequen-
cy [Hz]
Output voltage
[V AC]
Connection
type, input
Connection
type, output
Cable length,
output [cm]
Ambient tem-
perature
LTPEKE-
LTPEKE-
24V15W
24V30W
15
30
13.5
27
1.5
5
0.63
1.25
130 x 36
156 x 50
x 16
x 17
≥ 0.5
LTPEKE-
LTPEKE-
24V50W
24V75W
50
75
45
67.5
8
13
2.08
3.13
160 x 58
160 x 58
x 18
x 18
≥ 0.9
10%
200 – 240
50
24
Europlug
Plug-and-Play
20
-20 °C – 45 °C
EN
LTPEKE-
24V100W
100
90
17
4.17
164 x 57
x 17
65