6.9 Full water tank
If the water tank is full, the LED (
matically stops operation.
To empty the water tank, proceed as follows:
1. Press the ON/OFF button to switch off the air dehumidifier.
2. Carefully pull the water tank out backwards.
3. Remove the cover from the water tank in an upward direction.
4. Empty the water from the water tank into a sink.
5. Replace the water tank cover and slide the empty water tank into the air
dehumidifier.
After you have removed the water tank and put it back in, the air dehumidifier will wait three minutes
before automatically starting again in order to protect the built-in compressor against damage.
6.10 Automatic switch-off
To avoid damage to the air dehumidifier, dehumidifying is automatically stopped in the following cases
(automatic switch-off):
– If the temperature sensor detects a temperature below 0°C. Additional acoustic signals sound.
– If the temperature sensor records a temperature above 40°C. Additional acoustic signals sound.
If the air dehumidifier is stopped by automatic switch-off, when it is next switched on it will start with
the factory settings (fan speed high II, continuous dehumidifying ∞). If the air dehumidifier is switched
off with the power button, when it is next started up it will not be in factory settings but in the last
settings used.
6.11 Condensate hose
As an alternative to using the water tank, you can also route the extracted water directly into an outlet using
the supplied condensate hose.
1. Ensure that the air dehumidifier is switched off.
2. Pull out the water tank.
3. Connect the condensate hose as shown inside the LE 60.
4. Feed the hose through the opening in the water tank.
5. Slide the water tank back into the device and if necessary pull the condensate hose upwards so that there
are no kinks in the condensate hose.
6. Switch the air dehumidifier on again. The water extracted from the air is now drained directly into an outlet
through the condensate hose.
IMPORTANT
Ensure that there is sufficient gradient between the hose connector and the outlet to allow the accu-
mulating condensate water to flow away. Ensure that the end of the condensate hose is positioned flat
against the outlet.
) lights up and 10 acoustic signals are issued. The air dehumidifier auto-
20