38
38
Electrical Connection
1. Make sure that the iron voltage (see name plate) and the
line voltage match.
2. Turn the switch to or MIN.
3. The mains plug should only be inserted into a correctly
installed socket with earthing contact.
Connected Wattage
The three power levels of the appliances are as follows:
RA 5520 = 1400 - 1600 W
RA 5521 = 1800 - 2200 W
RA 5522 = 2000 - 2400 W
With this connected load a separate supply line protected by
a 16 A household circuit breaker is recommended.
CAUTION: Overload
• If you use extension leads, these should have a cable
cross-section of at least 1.5 mm².
• Do not use any multiple sockets, as this appliance is too
powerful.
Safety Switch
Your radiator has a safety switch which turns off the electricity
as soon as the appliance falls over. The safety switch prevents
dangerous situations caused by overheating.
CAUTION:
Always place the appliance in an upright position in order
that it is stable and in order to prevent malfunctions.
NOTE:
The appliance switches on again automatically as soon as it
is placed in an upright position.
Levels / Heating Power
Adjust the heating level by means of the selector switch.
Switch turned to level:
=
low power
=
medium power
=
high power
=
the appliance is off
NOTE:
Select low power, for example, for a small room. If this is
not enough, turn the radiator to the medium or high level.

Setting the Temperature

By regularly switching the radiator on and off, the thermostat
ensures that the desired temperature is maintained.
In order to find the ideal thermostat setting, please proceed
as follows:
RA 5520_RA 5521_RA 5522_IM
1. Turn the thermostat control to MAX.
2. As soon as the desired temperature has been reached,
turn the thermostat control slowly down until the radiator
turns itself off. The control lamp on the switch goes off.
The radiator will now automatically stay at the desired tem-
perature.
CAUTION:
When the appliance is no longer being used you should
always remove the mains plug.
Turning Off
If you would like to turn the radiator off, move the switch to
MIN or and then remove the plug from the socket. The
control lamp goes off.
Cleaning
WARNING:
Always remove the power cable from the socket and allow
the radiator to cool down before cleaning it.
CAUTION:
Do not use any type of detergent, abrasive or polish on the
housing of the radiator as this may damage the surface.
• Wipe off the radiator with a dry cloth in order to remove
dust.
• A damp cloth (not wet) can be used to remove stains.
Storage
• Remove the plug from the socket when you are not using
the appliance.
• Wind the mains cord economically onto the take-up.
• If the radiator is not going to be used for a prolonged
period it can be stored in its original packaging.

Technical Data

Model: ................................................RA 5520 / RA 5521 / RA 5522
Power supply: ...............................................220 - 240 V~, 50 / 60 Hz
Power consumption:
RA 5520: ..................................................................1400 - 1600 W
RA 5521: ..................................................................1800 - 2200 W
RA 5522: ..................................................................2000 - 2400 W
Protection class: .................................................................................
Net weight: ............................ approx. 9.00 kg / 11.30 kg / 12.90 kg
The right to make technical and design modifications in
the course of continuous product development remains
reserved.
This appliance has been tested according to all relevant
current CE guidelines, such as electromagnetic compatibility
and low voltage directives, and has been constructed in
accordance with the latest regulations.
15.06.18